How to Use This Manual Og g Congratulations on your decision to place your confidence in a superior Hague water treatment appliance. Recognized nationwide for built-in quality, dependability, and ease of service, this appliance represents state-of-the-art in home water treatment. We urge you to read this information carefully and review it again at any time you notice a change in your water or appliance. Later in the manual, there is a Troubleshooting section.
How To Get The Maximum Efficiency From Your Appliance 1. Maintain salt level at least 1/3 full; use solar salt or pellets and purchase a clean grade of salt. Use one or the other; do not mix pellet and solar salt. If potassium chloride is used in place of nugget or pellet salt, you must select the potassium option during the programming of the controller (see pg. 8-12). We do not recommend using Potassium Chloride if there is iron and/or manganese in your water. 3.
Checklist Before Installation 1. Water Pressure - Not less than 20 nor greater than 120 psi (1.4 - 8.4 bar) constant. (See Engineering Specifications, page 13.) 2. Water Temperature - Not less than 40° nor greater than 120°F (6°- 49° C). (See Engineering Specifications, page 13.) 3. Minimum Service Flow Rate Available To The Appliance - 3 gpm or equal to the backwash flow rate of your particular model. (See Engineering Specifications, page 13.
Do's And Don'ts SOME DO'S 1. Do install after the pressure tank on well water installations. 2. Do comply with all local building, plumbing and electrical codes. 3. Do install pressure-reducing valve if inlet pressure exceeds 90 psi. 4. Do install gravity drain on cabinets. 5. Do secure drain line on appliance and at drain outlet. SOME DON'TS 1. Do not install if checklist items are not satisfactory. 2. Do not install if incoming or outlet piping water temperature exceeds 120° Fahrenheit (49° C) .
Wh en 8z How- To Use The Bypass Valve The bypass valve is intended to provide isolation of the WaterMax appliance in the event of a system malfunction, leak, or if the use of untreated water for watering plants, shrubs, or lawns is not available otherwise. Facing your appliance from the front, the bypass is located on the main control valve (See ' below.) To engage the bypass, locate the cone-shaped knob on the right hand side, behind the controller. Turn the knob counter-clockwise until it stops.
Installation Guide 8z Start-up Procedure Figure 1 From Meter r From Well Drain Line Cold Water Hot Water Water Heater C7WATERIIAX Pressure Tank r Maintain a min. 2 in. air gap Use this diagram as a location and installation guide for your 60 Series water conditioner. To simplify installation and servicing, your WaterMax appliance includes a bypass valve required by the uniform plumbing code. A bypass system also provides access to untreated water when required (i.e.
Installation Guide & Start-up Procedure 1. Place the 60 Series in the desired location. Turn off the electricity and/or water supply to the water heater. Make sure the inlet, outlet and drain connections meet the applicable local codes. Check the arrows on the bypass valve to be sure the water flows in the proper direction. CAUTION: Do not plumb the appliance in backwards. 7. Connect the transformer power cord to the back of the controller. 8. Plug in the transformer. 9. Program the Appliance Control.
Setting And Using The Appliance Control Figure 2 SERVICE SETTINGS This section is recommended for qualified service personnel only. The appliance control must be set correctly for proper performance. FUNCTION: Used to enter SERVICE SETTINGS mode. All three OPERATING MODES can be selected and all operating parameters can be set for each OPERATING MODE when this button is activated. Press and hold (approximately 3 seconds) until display changes to "Set language???".
Setting And Using The Appliance Control (cont.) Description Of The Three WaterMax Operating Modes CAUTION: Be sure the controller is firmly "locked" onto the drive end cap assembly." The four tabs on top of the drive end cap will allow the clips on the bottom of the controller case to lock onto the end cap tabs. (See detail diagram on page 20; fig. 3.) MODE 1 TIMER MODE: Will regenerate based on frequency. Example: every 2 days or as specified up to 12 days. Time of regeneration can be set.
Setting And Using The Appliance Control (cont.) 3.04 Push the NEXT button to step to the next Parameter. The display will show: This parameter is used to record the tested iron content of the water. Iron ppm 000 (Hist) 3.04a Push the the SELECT and CHANGE buttons until the desired iron number is reached. In this example, set to: Iron ppm 002 (Hist) 3.05 Push the NEXT button to step to the next Parameter. The display will show: Mang.
Setting And Using The Appliance Control (cont.) 6.00 . Push the NEXT button to step to the next parameter. The display will show: Hard. Gr. 040 The 040 is the hardness number of the water tested. This number is to be the actual hardness reading and is not compensated for iron. 6,OOa Push and release the SELECT DIGIT button until the cursor ( ) is positioned in the display as follows: Hard. Gr. Q40. The cursor is now under the "ten" position. 6.
Setting And Using The Appliance Control (cont.) 14.00 Push the NEXT button to step to the next parameter. The display will show: Brine/Rinse 30.0 The "30.0" is the time, in minutes to the nearest tenth, for which the first brine and slow rinse cycles can be set. 14.00a Push the SELECT and CHANGE buttons until the desired combined brine and slow rinse cycle time is displayed. In this example, set to: Brine/Rinse 30.0 15.00 Push the NEXT button to step to the next parameter.
F4,11gineering Specifications 60 SERIES 63MAQ 63BEQ* 62AMQ **62APQ*** 62AKQ 62AJQ**** 63MXQ 63MDQ 0 0-2 0 0 0 0 Tannin (ppm) 0 Sulfur (ppm) - SulfurStat 0 0 0 0 0 0-5** 0 0 Iron (ppm) - ferrous - clear water • 0 0 12 0 12 2-12** 15 5 Maximum Compensated Hardness 90 90 110 90tt 90 90 90 60 Maximum Chlorine (ppm) 1 3 0 0 0 0 0 0 Minimum pH NA NA 7 7 7 7 7 6.3 Filtration - nominal rating (microns) 20 25 20 20 20 20 20 20 1/5,850 1/5,850 1.
Mode I Setting Chart 63MAQ 63BEQ * 63MXQ 63MDQ 62AMQ 62APQ ** *** 62AKQ 62AJQ **** YES YES YES YES YES YES YES YES As required -- As required – As required YES 1 or 2 1 or 2 1 or 2 1 or 2 -- As required YES YES YES YES Backwash 1 (minutes) 1 1 1 — 2• -- — — Brine rinse (minutes) 7 7 7 — 7 -- --- –' Backwash 2 (minutes) 3 3 3 2 --- -- --- 5,850 1 lb. 5,850 1 lb, 9,360 1.6 lb. 5,850 1 lb.
Mode II Setting Chart 60 SERIES 63MAQ 63BEQ * 63MXQ 63MDQ ** 62AMQ 62APQ ** .*** 62AKQ ** 62AJQ **** YES YES YES NO YES NO NO YES As -- As required YES OR NO — — — — As required YES OR NO — 2 -- '– -` — 7 — -- -- -- 2 9,360 1.6 lb. — 5,850 1 lb.
WaterMax Filters 61 AAN 61 AAE -BWO 61 AAR -BWO 61 AAS -BWO 61 AAF -BWO 10,000 N/A N/A N/A N/A Sulphur H 2 S (2 ppm) 5 N/A N/A N/A N/A Iron (ppm) 20 N/A N/A N/A N/A Minimum pH 7 N/A N/A 5' N/A Manganese Greensand Activated Carbon Filter Ag Calcite/Corsex multi-Grade Media amount (cu. ft.) 1.25 1 1.25 1.25 1 Cont. flow rate (gpm) 6 6 6 6 6 Peak flow rate (gpm) 10 10 10 10 12 Backwash rate (gpm) 7 5 5 7 7 Brine line flow control (gpm) .
Troubleshooting Problem Cause No soft water after regeneration. No salt in brine tank. Add salt. Sediment in brine tank has plugged the brine line and/or air check. (See Fig. 4.) Remove the brine line and flush clean. Clean air check. Clean brine tank. Refill flow control is plugged. (See Fig. 9.) Remove brine piston housing and clear debris from the flow control. Drain line is pinched, frozen or restricted. (See Fig. 1.) Straighten, thaw or unclog the drain li ne. Clogged injector assembly.
Troubleshooting Problem Cause Flow indicator blinks when water is not being used. (Fig. 2) There is a leak in your household plumbing system. Repair the leak. No read-out in display. Electric cord is unplugged. Plug in transformer. (Fig. 1.) No electric power at outlet. Check power source. Make sure outlet is not controlled by a switch. Defective transformer (fig. 3). Test with volt meter for 12 VAC at control. If less than 10 VAC or greater than 14 VAC, replace transformer.
Troubleshooting Problem Salty water Solution Cause Plugged injector. Clean injector screen, nozzle and throat (See Fig. 6) Low water pressure. Maintain minimum pressure of 30 psi (See Engineering Specs.) Drain line or flow control is restricted. Remove restriction. Brine line restricted or crimped. Remove restriction, replace if crimped. Excessive amount of water in brine cabinet. Verify correct water level relative to salt setting.
Parts - Figure 3-HOOK-UP/COVER ASSEMBLY ITEM NO. QTY. PART NO.
Parts — Figure 4-BRINE TANK ASSEMBLY 1 2 3 4 5 6 7 8 PART# 54006 90103 54525 54007 CO700A 54008 54009 54003 54509 DESCRIPTION Brine Tank Cover Brine Well Cap Safety Shutoff Assembly Support Panel (BT) Cabinet Overflow Brine Well Grid Plate Cabinet Brine Tank Assembly 21 QUANITY 1 1
Parts – Figure 5-Tank/Cabinet Assembly PART# 1 93809 2 93870 3 90614 4 93808 5 93835 6 90238 7 90819 8 93838 9 90615 10 93833 11 90828 12 95301T-JG 95302T-BWO 13 54003 14 93501 15 54508 54514 54516 16 54005 DESCRIPTION QUANITY 2 Screw 4 Screw 1 Drian End Cap Assembly 0-Ring 2 Sleeve 2 Resin Tank Fill Plug 1 Fill Plug 0-Ring 2 0-Ring 2 Bypass Assembly 1 Cord Clip 1 1 0-Ring Drive End Cap Assembly 1 Drive End Cap Assembly, Backwash Only 1 Cabinet 1 Injector Assembly 1 Resin Tank (3 Compartment) 1 Resin Tank
Parts — Figure 6-Injector Assembly ITEM NO. QTY. PART NO.
Parts – Injector Assembly 93223 Injector Throat: In conjunction with the Injector Nozzle, Part # 93221, it creates the vacuum that draws the brine solution from the brine cabinet. The center hole should be clear of debris,round and undamaged. The Throat should be pressed flush into the opening in the valve. If the Throat is removed, it must be replaced with a new one. 93220 Thick Injector Seal: Seals between the Injector Nozzle and the Main Valve Body.
Parts Figure 7 -Bypass Assembly ITEM NO. QTY. PART NO. DESCRIPTION 1 2 12 1 90807 90262 3 4 2 6 93808 5 1 6 7 1 1 8 1 9 10 1 1 11 1 90802 90252 90222 90827 90246 90616 90218 90803 ITEM NO. QTY. PART NO. DESCRIPTION Screw 12 1 90263 Bypass Endcap - right Bypass Endcap - left 0-Ring 13 14 2 1 90828 0-Ring Screw 15 1 90226 90812 Test Port Valve Tubing 4.
Parts — Bypass Assembly 90246 Bypass Housing: Makes the connection between the plumbing and Main Valve Body. Also, contains the "Hard Water" Blending Valve and Bypass Piston. The recommended seal for the 1 '/" male inlet-outlet threads is the plastic Hook-up Nut (90251), 0-ring (90837), and Copper Adapter (90254). Make sure the 0-ring is between the Housing and Copper Adapter.
Parts — Figure 8-Drive End Cap Assembly ITEM NO. QTY. PART NO. DESCRIPTION ITEM NO. QTY. PART NO.
Parts – Drive End Cap Assembly 93583 Drive End Cap: Seals the two openings on the Main Valve Body. The larger diameter opening is sealed with an 0-ring used as an axial or "face" seal. The 0-ring sits in a groove in the End Cap. This groove must be free of defects such as pits or scratches and also free of debris. The smaller diameter seal is accomplished with an 0-ring used as a radial seal. The 0-ring should be placed on the male boss on the End Cap.
Parts — Figure 9 - Brine Valve Housing Assembly ITEM NO. QTY. PART NO. DESCRIPTION 1 2 3 4 5 6 7 8 9 10 1 1 1 93620 90821 93260 1 1 1 1 1 93878 93254 90843 93805 93243-JG 1 2 200199 90818 Piston Assembly (includes 0-ring & Spring) 0-Ring Housing Quad Ring Quad Ring Retainer .
Parts – Brine Valve Housing Assembly 93260 Housing: Should have a Quad-ring for the Piston seal. The Quad-ring (4) is held in place by the quad ring retainer (5). The brine valve housing has four retaining lugs that secure the quad ring retainer. Just inside the entrance hole for the Brine Piston (1) is a concave seat area that must be free of defects such as nicks, indentations or debris. If any defects are detected by visual inspection, repair or replace as needed.
Parts — Figure 10 - Fill Plug Assembly ITEM NO. QTY. PART NO. DESCRIPTION 1 2 1 2 90238 90819 Fill Plug 0-Ring (1) 90238 Fill Plug: The Fill Plug seals the media access ports in the Media Tank. Care should be taken that the 0-ring seal areas are kept clean and free of debris. Also, both 0rings should be in the proper locations, one under the flange and one in the groove. Do not overtighten the Fill Plug when assembling. When the flange comes into contact with the Media Tank, stop tightening.
Parts - Figure 11 - Drain End Cap Assembly ITEM NO. QTY. PART NO. 1 93808 1 90268 2 1 H2086-3.0 3 1 90267 4 1 DESCRIPTION O-Rinq Drain End Cap Drain Line Flow Control Retainer (1) 90268 Drain End Cap: Seals the left opening on the Main Valve Body. The opening is sealed with an 0-ring used as axial or "face" seal. The 0-ring sits in a groove in the End Cap. This groove must be free of defects such as pits or scratches and also free of debris.
Parts - Figure 12 - Safety Shutoff ITEM NO. QTY. PART NO.
Parts — Figure 13 - Brine Valve Elbow Installation 0 . a 3/8" Plastic Gripper 1 /2" Retainer Sleeve The nut, gripper and retainer sleeve are a 3 piece assembly that can come apart if removed from the elbow body. Parts must be re-assembled exactly as shown to function properly. When connecting the 3/8" polytube, it is first necessary to assemble the nut, gripper and retainer sleeve on the tubing before inserting the plastic insert. Screw the nut on the elbow body.
25 Year Limited Warranty will not be liable for, nor will it pay service call or labor charges incurred or expended with respect to this warranty. TO PLACE THIS EQUIPMENT UNDER WARRANTY, THE WARRANTY REGISTRATION CARD MUST BE COMPLETED AND RETURNED BY THE ORIGINAL OWNER TO HAGUE QUALITY WATER INTERNATIONAL WITHIN 30 DAYS OF INSTALLATION.
Brine Cabinet Data Based on the water level measured from the bottom of the WATERMAX brine cabinet WITH GRID PLATE, the following depths correlate to the amount of salt used per regeneration: DEPTH (inches) SALT (lbs.) 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 .74 1.5 2.2 3.0 3.7 4.4 5.2 5.9 6.6 7.4 8.1 8.8 9.6 10.3 11.0 11.8 12.5 13.3 14.4 PLEASE STUDY THE ABOVE CHART TO CONFIRM THIS INFORMATION. WaterMax Brine Cabinet Statistics No Salt With Salt 1" = .791 gallons 1" = 2.2148 lbs.