Electrical Requirement
Power Supply
208/230V, 1 Phase,
60 HZ
Operating Voltage Range 187~253 VAC
Recommended Fuse/Breaker Size 30A
MCA 20A
Cooling Performance
Rated Cooling Capacity 18,000 BTU
Cooling Capacity Range 6,500~23,200 BTU
Rated Power input 1,560 W
SEER 19.0
EER 11.5
Moisture Removal 3.8 Pt./h
Heating Performance
Rated Heating Capacity 20,000 BTU
Heating Capacity Range 5,100~24,000 BTU
Rated Power Input 1,900 W
HSPF 10.0
CUS
Intertek
For more information visit us:
www.Haierductless.com
www.Haierductlesshelp.com
Connecting cable to indoor units must be 14/4 AWG unshielded stranded
copper. Cable must be ran continuous, without splicing.
Accessories
Pipe Length
Minimum Pipe Length 10 ft
Maximum Pipe Length 83 ft
Maximum Pipe Height Dierence 50 ft
Flare Connections
Liquid 1/4”
Vapor 1/2”
Wired Controller
Controller must be ordered separately.
Compatible with the Simplied (QACT17A) and
Programmable (YR-E16B) wall controllers.
Built-in WiFi
Supply Plenum
UAPT0912A
Filter Box
UAMFB0912A
Operating Range
Cooling With Wind Bae 14~115°F (-10~46°C)
Cooling Without Wind Bae 23~115°F (-5~46°C)
Heating -31~75°F (-35~24°C)