Brochure

28 29
Arctic Series
Multi-Zone
With the integration of Haier Heat Plus technology, the Arctic Series provides an exceptional experience for year-round
comfort. The system is capable of providing 100% rated heating capacity at 5°F and toasty warm air at -15°F.
Arctic features, benets, and performance, available now for multi-zone applications.
FlexFit Series
Haier FlexFit multi-zone systems can operate from 2 to 4 indoor units
simultaneously with individual zone control. With outdoor units able to
supply up to 48,000 BTU of heating/cooling capacity, the FlexFit Multi-
Zone series gives you freedom like never before.
Multi-Zone
Compressor Type:
DC Inverter Driven Rotary
Voltage/Cycle/Phase:
208-230/60/1
Operating Range (
O
F):
Outdoor Units
2U18MS2VHB 3U24MS2VHB 4U36MS2VHB
Cooling Non-ducted
Rated Capacity Btu/hr 17,400 22,600 34,000
Capacity Range Btu/hr 4,400-19,400 5,000-24,500 5,000-36,000
Rated Power Input W 1,650 2,250 3,770
SEER/EER 16.0/10.5 18.0/10.0 18.0/9.0
Cooling Ducted
Rated Capacity Btu/hr 15,000 21,000 31,000
Capacity Range Btu/hr 4,400-19,400 5,000-23,000 5,000-34,000
Rated Power Input W 1,760 2,416 3,590
SEER/EER 16.0/8.5 16.0/8.5 16.0/8.5
Heating Non-ducted
Rated Heating Capacity 47°F Btu/hr 19,200 23,000 34,600
Heating Capacity Range Btu/hr 6,100-22,100 6,100-25,500 6,100-36,500
Rated Power Input W 1,570 1,700 2,650
HSPF 9.0 10.0 10.0
Rated Heating Capacity 17°F Btu/hr 13,000 15,000 22,000
Heating Ducted
Rated Heating Capacity 47°F Btu/hr 18,000 22,000 33,000
Heating Capacity Range Btu/hr 6,100-22,100 6,100-25,000 6,100-35,000
Rated Power Input W 1,700 2,100 3,000
HSPF 8.5 8.5 9.0
Rated Heating Capacity 17°F Btu/hr 10,000 14,000 21,000
Outdoor Unit
Maximum Fuse Size A 25 25 30
Minimum Circuit Amp A 15 18 23
Outdoor Fan Speed RPM 300 ~ 900 300 ~ 900 300 ~ 900
Outdoor Noise Level dB 53 54 56
Dimension: Height in (mm) 27 1/16 (688) 28 3/4 (730) 33 1/16 (840)
Dimension: Width in (mm) 31 7/8 (810) 33 7/8 (860) 37 5/16 (948)
Dimension: Depth in (mm) 11 5/16 (288) 12 1/8 (308) 13 3/8 (340)
Weight (Ship/Net)- lbs (kg) 102.5/95.9 (46.5/43.5) 123.4/116.8 (56/53) 191.8/167.5 (87/76)
Connectable Indoor unit quantity 2 2 or 3 2, 3 or 4
Refrigerant Lines
Connections Flare Flare Flare
Liquid O.D. in 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4
Suction O.D. in 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 1/2
Factory Charge Oz 49.5 67.0 113.0
Maximum Line Length Ft / m 100/30 200/60 230/70
Maximum Height Ft / m 50/15 50/15 50/15
Maximum Line Length (each individual indoor unit) Ft / m 65/25 82/25 82/25
Scan this code with your smart
device to learn more about
FlexFit multi-zone mini-splits.
Specications
2 Zones 3 Zones 4 Zones
3 outdoor units. 14 indoor units. 1,000+ combinations.
-22 1151450-4
-15
Cooling
Heating
75
Specications
Outdoor Units
2U20EH2VHA 3U24EH2VHA 4U36EH2VHA
Cooling Non-
Ducted
Rated Capacity Btu/hr 18,100 22,000 34,000
Capacity Range Btu/hr 7000-20000 6000-23600 6000-38000
Rated Power Input W 1448 1760 2,740
SEER/ EER 17/12.5 18.5/12.5 20 /12.5
Cooling Ducted
Rated Capacity Btu/hr 18,100 21,000 34,400
Capacity Range Btu/hr 6000-19000 6000-22300 6000-37000
Rated Power Input W 1724 2000 2,740
SEER/EER 15/10.5 15/10.5 17.00 /10.00
Heating Non-
Ducted
Rated Heating Capacity 47°F Btu/hr 20,000 24,000 36,000
Heating Capacity Range Btu/hr 8000-23000 8000-30600 8000-39000
Rated Power Input W 1504 1572 2,710
HSPF 10.5 10.5 10.5
COP @ 5°F 2.0 2.0 2.0
Max. Heating Capacity 5°F Btu/hr 23000 24000 36,000
Max. Heating Capacity -15°F Btu/hr 17000 18000 25,000
Heating Ducted
Rated Heating Capacity 47°F Btu/hr 20,000 22,000 35,000
Heating Capacity Range Btu/hr 8000-21000 8000-28600 8000-39000
Rated Power Input W 2255 2230 2710
COP/ COP @ 5°F 2.94/1.9 3/1.9 2.64/1.9
HSPF 9.6 9.3 10.5
Max. Heating Capacity 5°F Btu/hr 19000 20000 35,000
Max. Heating Capacity -15°F Btu/hr 15000 16000 25,200
Power Supply
Voltage, Cycle, Phase V/Hz/- 208-230/60/1 208-230/60/1 208-230/60/1
Wire Size between ID and OD 14/4 AWG Stranded 14/4 AWG Stranded 14/4 AWG Stranded
Compressor Type DC Inverter Driven Rotary DC Inverter Driven Rotary DC Inverter Driven Rotary
Maximum Fuse Size A 25 25 40
Minimum Circuit Amp A 15 16 30
Outdoor Unit
Outdoor Fan Speed RPM 300~900 300~900 300~900
Outdoor Noise Level dB 56 56 55
Dimension: Height in (mm) 33.1(840) 33.1(840) 38.0 (965)
Dimension: Width in (mm) 37.3(948) 37.3(948) 37.4(950)
Dimension: Depth in (mm) 13.4(340) 13.4(340) 14.6(370)
Weight (Ship/Net)- lbs (kg) 202.3/185.6 (91.7/84.2) 205.9/189.5 (93.4/85.9) 241/221 (109.7/100.6)
Connectable Indoor unit quantity 2 2 or 3 2 3 or 4
Refrigerate Lines
Connections Flare Flare Flare
Liquid O.D. in 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4
Suction O.D. in 3/8 3/8 3/8 3/8 1/2 3/8 3/8 3/8 1/2
Factory Charge Oz 99 99 113
Maximum Line Length Ft / m 164/50 196/60 230/70
Maximum Height Ft / m 50/15 50/15 50/15
Maximum Line Length for each individual indoor
unit Ft / m
82/25 82/25 82/25
2 Zones 3 Zones 4 Zones
Compressor Type:
DC Inverter Driven Rotary
Voltage/Cycle/Phase:
208-230/60/1
Operating Range (
O
F):
-22 1151450-4
-15
Cooling
Heating
75