Submittals Next Gen Arctic Series Rev. Feb 2021 1U09EH2VHE / AW09EH2VHD 1U09EH2VHE / AB09SC2VHA 1U09EH2VHE / USYF09UCDWA 1U09EH2VHE / USYM09UCDSA 1U12EH2VHE / AW12EH2VHD 1U12EH2VHE / AB12SC2VHA 1U12EH2VHE / USYF12UCDWA 1U12EH2VHE / USYM12UCDSA 1U18EH2VHE / AW18EH2VHD 1U18EH2VHE / AB18SC2VHA 1U18EH2VHE / USYF18UCDWA 1U18EH2VHE / USYM18UCDSA C US Intertek For more information visit us: www.Haierductless.com www.Haierductlesshelp.
Revision History Rev. April 2020 - Submittal edition release. Rev. July 2020 - Added ODU floor mounting dimensions diagrams. Rev. Aug 2020 - Controller updates. Rev. Feb 2021 - Ducted, console, and cassette indoor units added. Capacity tables revised.
Next Gen Arctic Series Submittal 9000 BTU/HR HIGHWALL INVERTER DRIVEN HEAT PUMP SYSTEM 1U09EH2VHE / AW09EH2VHD Job Name:___________________________________ Approval:____________________________________ Purchaser:___________________________________ Date: _______________________________________ Submitted To: ________________________________ Submitted By: ________________________________ Construction: ________________________________ Unit: ________________________________________ Reference:___________
Next Gen Arctic Series Submittal 9000 BTU/HR HIGHWALL INVERTER DRIVEN HEAT PUMP SYSTEM 1U09EH2VHE / AW09EH2VHD Indoor Unit Outdoor Unit 12 7/8 x 39 3/4 x 8 3/4 in (327 x 1009 x 223 mm) 16 x 42 3/4 x 11 5/8 in Crated (HxWxD) (405 x 1085 x 296 mm) Airflow CFM 583/383/324/264/240 (Turbo/High/Med/Low/Quiet) Indoor Sound Level dB 45/37/34/31/25 (Turbo/High/Med/Low/Quiet) Motor Rating (HP) 0.04 Heat Exchanger Fin Type Blue Fin Weight (Ship/Net) 35.7/27.
Next Gen Arctic Series Submittal 9000 BTU/HR COMPACT CASSETTE TYPE INDOOR INVERTER DRIVEN HEAT PUMP SYSTEM 1U09EH2VHE / AB09SC2VHA Job Name:___________________________________ Approval:____________________________________ Purchaser:___________________________________ Date: _______________________________________ Submitted To: ________________________________ Submitted By: ________________________________ Construction: ________________________________ Unit: ________________________________________ R
Next Gen Arctic Series Submittal 9000 BTU/HR COMPACT CASSETTE TYPE INDOOR INVERTER DRIVEN HEAT PUMP SYSTEM 1U09EH2VHE / AB09SC2VHA Indoor Unit Crated (HxWxD) Panel Uncrated Dimension (HxWxD) Panel Crated (HxWxD) Airflow CFM (Turbo/High/Med/Low/Quiet) Indoor Sound Level dB (Turbo/High/Med/Low/Quiet) Motor Rating (HP) Heat Exchanger Fin Type Condensate Pump Drain Pipe Size OD Weight (Ship/Net) 10 1/4 x 22 1/2 x 22 1/2 in (260 x 570 x 570 mm) 15 x 28 1/4 x 26 3/4 in (380 x 718 x 680 mm) 2 3/8 x 27 1/2 x 27
Next Gen Arctic Series Submittal 9000 BTU/HR COMPACT CASSETTE TYPE INDOOR INVERTER DRIVEN HEAT PUMP SYSTEM AB09SC2VHA ⑥ ⑥ Part Name 1 Vapor Pipe 2 Liquid Pipe 3 Drain Pump Outlet 4 Fresh Air Inlet 5 Air Return Grille 6 Air Supply More than 59 (1500) to wall on all sides 4 3/4 (120) ③ ② ① 1 inch recess between ceiling surface and bottom of unit without panel on.
Next Gen Arctic Series Submittal 9000 BTU/HR FLOOR CONSOLE INVERTER DRIVEN HEAT PUMP SYSTEM 1U09EH2VHE / USYF09UCDWA Job Name:___________________________________ Approval:____________________________________ Purchaser:___________________________________ Date: _______________________________________ Submitted To: ________________________________ Submitted By: ________________________________ Construction: ________________________________ Unit: ________________________________________ Reference:_____
Next Gen Arctic Series Submittal 9000 BTU/HR FLOOR CONSOLE INVERTER DRIVEN HEAT PUMP SYSTEM 1U09EH2VHE / USYF09UCDWA Indoor Unit Outdoor Unit 23 3/4 x 27 1/2 x 8 1/4 in Uncrated Dimension (HxWxD) (600 x 700 x 210 mm) 27 1/2 x 30 3/4 x 12 in Crated (HxWxD) (695 x 783 x 303 mm) Airflow CFM 264/235/205/176/147 (Turbo/High/Med/Low/Quiet) Indoor Sound Level dB 40/36/32/25/20 (Turbo/High/Med/Low/Quiet) Motor Rating (HP) 0.04 Heat Exchanger Fin Type Blue Fin Weight (Ship/Net) 43.4/36.
Next Gen Arctic Series Submittal 9000 BTU/HR FLOOR CONSOLE INVERTER DRIVEN HEAT PUMP SYSTEM USYF09UCDWA 24 3/4 (630) 2 1/2 (65) 5/8 (16) 3/4 (20) 4 1/2 (115) 8 5/8 (220) 3/4 (20) 27 1/2 (700) 23 5/8 (600) 3 1/8 (80) 3 1/2 (90) 8 3/4 (223) ⑤ ② 7 1/8 (181) 3 1/2 (90) 3 1/8 (80) ③ ④ ② 26 1/8 (663) 25 1/8 (639) 16 (406) 3 1/4 (84) 3 1/4 (84) ⑦ ⑦ 5 7/8 (150) 21 1/8 (535) 9 7/8 (252) 19 3/8 (492) 9 (228) 5 3/4 (145) ⑥ # 1 2 3 4 5 6 7 Description Screw holes for floor install Side knockout
Next Gen Arctic Series Submittal 9000 BTU/HR MID-STATIC DUCTED INVERTER DRIVEN HEAT PUMP SYSTEM 1U09EH2VHE / USYM09UCDSA Job Name:___________________________________ Approval:____________________________________ Purchaser:___________________________________ Date: _______________________________________ Submitted To: ________________________________ Submitted By: ________________________________ Construction: ________________________________ Unit: ________________________________________ Reference:_
Next Gen Arctic Series Submittal 9000 BTU/HR MID-STATIC DUCTED INVERTER DRIVEN HEAT PUMP SYSTEM 1U09EH2VHE / USYM09UCDSA Outdoor Unit Indoor Unit Compressor DC inverter Driven Rotary 27 1/2 x 35 x 13 7/8 in Uncrated Dimension (HxWxD) (697 x 890 x 353 mm) 31 1/2 x 41 1/8 x 18 1/8 in Crated (HxWxD) (800 x 1046 x 460 mm) Outdoor Sound Rating dB 54 Heat Exchanger Fin Type Blue Fin Weight (Ship/Net) 115.5/98.3 lbs Factory Refrigerant Charge R-410A (56.
Next Gen Arctic Series Submittal 9000 BTU/HR MID-STATIC DUCTED INVERTER DRIVEN HEAT PUMP SYSTEM USYM09UCDSA 12 1/2 (317) 7 5/8 (195) ① ⑤ 15 3/4 (400) ⑥ 1 (25) 1 1/8 (30) 6 1/2 (166) ④ ③ Air flow 9 3/8 (238) ⑦ ② 1 3/8 (35) 1 3/4 (44) 9 3/4 (248) 5 (128) 6 1/4 (158) 3 7/8 (100) Reversable fresh air supply adapter 27 1/2 (700) 24 3/8 (620.
Next Gen Arctic Series Submittal 12000 BTU/HR HIGHWALL INVERTER DRIVEN HEAT PUMP SYSTEM 1U12EH2VHE / AW12EH2VHD Job Name:___________________________________ Approval:____________________________________ Purchaser:___________________________________ Date: _______________________________________ Submitted To: ________________________________ Submitted By: ________________________________ Construction: ________________________________ Unit: ________________________________________ Reference:__________
Next Gen Arctic Series Submittal 12000 BTU/HR HIGHWALL INVERTER DRIVEN HEAT PUMP SYSTEM 1U12EH2VHE / AW12EH2VHD Indoor Unit Outdoor Unit 12 7/8 x 39 3/4 x 8 3/4 in (327 x 1009 x 223 mm) 16 x 42 3/4 x 11 5/8 in Crated (HxWxD) (405 x 1085 x 296 mm) Airflow CFM 597/524/430/344/324 (Turbo/High/Med/Low/Quiet) Indoor Sound Level dB 46/42/37/31/27 (Turbo/High/Med/Low/Quiet) Motor Rating (HP) 0.04 Heat Exchanger Fin Type Blue Fin Weight (Ship/Net) 35.7/27.
Next Gen Arctic Series Submittal 12000 BTU/HR COMPACT CASSETTE TYPE INDOOR INVERTER DRIVEN HEAT PUMP SYSTEM 1U12EH2VHE / AB12SC2VHA Job Name:___________________________________ Approval:____________________________________ Purchaser:___________________________________ Date: _______________________________________ Submitted To: ________________________________ Submitted By: ________________________________ Construction: ________________________________ Unit: ________________________________________
Next Gen Arctic Series Submittal 12000 BTU/HR COMPACT CASSETTE TYPE INDOOR INVERTER DRIVEN HEAT PUMP SYSTEM 1U12EH2VHE / AB12SC2VHA Indoor Unit Crated (HxWxD) Panel Uncrated Dimension (HxWxD) Panel Crated (HxWxD) Airflow CFM (Turbo/High/Med/Low/Quiet) Indoor Sound Level dB (Turbo/High/Med/Low/Quiet) Motor Rating (HP) Heat Exchanger Fin Type Condensate Pump Drain Pipe Size OD Weight (Ship/Net) 10 1/4 x 22 1/2 x 22 1/2 in (260 x 570 x 570 mm) 15 x 28 1/4 x 26 3/4 in (380 x 718 x 680 mm) 2 3/8 x 27 1/2 x 27
Next Gen Arctic Series Submittal 12000 BTU/HR COMPACT CASSETTE TYPE INDOOR INVERTER DRIVEN HEAT PUMP SYSTEM AB12SC2VHA ⑥ ⑥ Part Name 1 Vapor Pipe 2 Liquid Pipe 3 Drain Pump Outlet 4 Fresh Air Inlet 5 Air Return Grille 6 Air Supply More than 59 (1500) to wall on all sides 4 3/4 (120) ③ ② ① 1 inch recess between ceiling surface and bottom of unit without panel on.
Next Gen Arctic Series Submittal 12000 BTU/HR FLOOR CONSOLE INVERTER DRIVEN HEAT PUMP SYSTEM 1U12EH2VHE / USYF12UCDWA Job Name:___________________________________ Approval:____________________________________ Purchaser:___________________________________ Date: _______________________________________ Submitted To: ________________________________ Submitted By: ________________________________ Construction: ________________________________ Unit: ________________________________________ Reference:____
Next Gen Arctic Series Submittal 12000 BTU/HR FLOOR CONSOLE INVERTER DRIVEN HEAT PUMP SYSTEM 1U12EH2VHE / USYF12UCDWA Indoor Unit Outdoor Unit 23 3/4 x 27 1/2 x 8 1/4 in (600 x 700 x 210 mm) 27 1/2 x 30 3/4 x 12 in Crated (HxWxD) (695 x 783 x 303 mm) Airflow CFM 294/264/235/205/176 (Turbo/High/Med/Low/Quiet) Indoor Sound Level dB 42/38/34/26/21 (Turbo/High/Med/Low/Quiet) Motor Rating (HP) 0.04 Heat Exchanger Fin Type Blue Fin Weight (Ship/Net) 43.4/36.
Next Gen Arctic Series Submittal 12000 BTU/HR FLOOR CONSOLE INVERTER DRIVEN HEAT PUMP SYSTEM USYF12UCDWA 24 3/4 (630) 2 1/2 (65) 5/8 (16) 3/4 (20) 4 1/2 (115) 8 5/8 (220) 3/4 (20) 27 1/2 (700) 23 5/8 (600) 3 1/8 (80) 3 1/2 (90) 8 3/4 (223) ⑤ ② 7 1/8 (181) 3 1/2 (90) 3 1/8 (80) ③ ④ ② 26 1/8 (663) 25 1/8 (639) 16 (406) 3 1/4 (84) 3 1/4 (84) ⑦ ⑦ 5 7/8 (150) 21 1/8 (535) 9 7/8 (252) 19 3/8 (492) 9 (228) 5 3/4 (145) ⑥ # 1 2 3 4 5 6 7 Description Screw holes for floor install Side knockou
Next Gen Arctic Series Submittal 12000 BTU/HR MID-STATIC DUCTED INVERTER DRIVEN HEAT PUMP SYSTEM 1U12EH2VHE / USYM12UCDSA Job Name:___________________________________ Approval:____________________________________ Purchaser:___________________________________ Date: _______________________________________ Submitted To: ________________________________ Submitted By: ________________________________ Construction: ________________________________ Unit: ________________________________________ Reference:
Next Gen Arctic Series Submittal 12000 BTU/HR MID-STATIC DUCTED INVERTER DRIVEN HEAT PUMP SYSTEM 1U12EH2VHE / USYM12UCDSA Outdoor Unit Indoor Unit Compressor DC inverter Driven Rotary 27 1/2 x 35 x 13 7/8 in Uncrated Dimension (HxWxD) (697 x 890 x 353 mm) 31 1/2 x 41 1/8 x 18 1/8 in Crated (HxWxD) (800 x 1046 x 460 mm) Outdoor Sound Rating dB 54 Heat Exchanger Fin Type Blue Fin Weight (Ship/Net) 124.8/107.6 lbs Factory Refrigerant Charge R-410A (62.
Next Gen Arctic Series Submittal 12000 BTU/HR MID-STATIC DUCTED INVERTER DRIVEN HEAT PUMP SYSTEM USYM12UCDSA 12 1/2 (317) 7 5/8 (195) ① ⑤ 15 3/4 (400) ⑥ 1 (25) 1 1/8 (30) 6 1/2 (166) ④ ③ Air flow 9 3/8 (238) ⑦ ② 1 3/8 (35) 1 3/4 (44) 9 3/4 (248) 5 (128) 6 1/4 (158) 3 7/8 (100) Reversable fresh air supply adapter 27 1/2 (700) 24 3/8 (620.
Next Gen Arctic Series Submittal 18000 BTU/HR HIGHWALL INVERTER DRIVEN HEAT PUMP SYSTEM 1U18EH2VHE / AW18EH2VHD Job Name:___________________________________ Approval:____________________________________ Purchaser:___________________________________ Date: _______________________________________ Submitted To: ________________________________ Submitted By: ________________________________ Construction: ________________________________ Unit: ________________________________________ Reference:__________
Next Gen Arctic Series Submittal 18000 BTU/HR HIGHWALL INVERTER DRIVEN HEAT PUMP SYSTEM 1U18EH2VHE / AW18EH2VHD Indoor Unit Outdoor Unit 13 1/4 x 44 3/8 x 9 in (337 x 1126 x 230 mm) 16 1/2 x 47 1/2 x 13 1/2 in Crated (HxWxD) (418 x 1206 x 342 mm) Airflow CFM 636/541/436/330/259 (Turbo/High/Med/Low/Quiet) Indoor Sound Level dB 47/41/38/35/29 (Turbo/High/Med/Low/Quiet) Motor Rating (HP) 0.07 Heat Exchanger Fin Type Blue Fin Weight (Ship/Net) 45.2/36.
Next Gen Arctic Series Submittal 18000 BTU/HR COMPACT CASSETTE TYPE INDOOR INVERTER DRIVEN HEAT PUMP SYSTEM 1U18EH2VHE / AB18SC2VHA Job Name:___________________________________ Approval:____________________________________ Purchaser:___________________________________ Date: _______________________________________ Submitted To: ________________________________ Submitted By: ________________________________ Construction: ________________________________ Unit: ________________________________________
Next Gen Arctic Series Submittal 18000 BTU/HR COMPACT CASSETTE TYPE INDOOR INVERTER DRIVEN HEAT PUMP SYSTEM 1U18EH2VHE / AB18SC2VHA Indoor Unit Crated (HxWxD) Panel Uncrated Dimension (HxWxD) Panel Crated (HxWxD) Airflow CFM (Turbo/High/Med/Low/Quiet) Indoor Sound Level dB (Turbo/High/Med/Low/Quiet) Motor Rating (HP) Heat Exchanger Fin Type Condensate Pump Drain Pipe Size OD Weight (Ship/Net) 10 1/4 x 22 1/2 x 22 1/2 in (260 x 570 x 570 mm) 15 x 28 1/4 x 26 3/4 in (380 x 718 x 680 mm) 2 3/8 x 27 1/2 x 27
Next Gen Arctic Series Submittal 18000 BTU/HR COMPACT CASSETTE TYPE INDOOR INVERTER DRIVEN HEAT PUMP SYSTEM AB18SC2VHA ⑥ ⑥ Part Name 1 Vapor Pipe 2 Liquid Pipe 3 Drain Pump Outlet 4 Fresh Air Inlet 5 Air Return Grille 6 Air Supply More than 59 (1500) to wall on all sides 4 3/4 (120) ③ ② ① 1 inch recess between ceiling surface and bottom of unit without panel on.
Next Gen Arctic Series Submittal 18000 BTU/HR FLOOR CONSOLE INVERTER DRIVEN HEAT PUMP SYSTEM 1U18EH2VHE / USYF18UCDWAA Job Name:___________________________________ Approval:____________________________________ Purchaser:___________________________________ Date: _______________________________________ Submitted To: ________________________________ Submitted By: ________________________________ Construction: ________________________________ Unit: ________________________________________ Reference:___
Next Gen Arctic Series Submittal 18000 BTU/HR FLOOR CONSOLE INVERTER DRIVEN HEAT PUMP SYSTEM 1U18EH2VHE / USYF18UCDWA Indoor Unit Outdoor Unit 23 3/4 x 27 1/2 x 8 1/4 in (600 x 700 x 210 mm) 27 1/2 x 30 3/4 x 12 in Crated (HxWxD) (695 x 783 x 303 mm) Airflow CFM 341/311/282/252/223 (Turbo/High/Med/Low/Quiet) Indoor Sound Level dB 46/42/37/33/28 (Turbo/High/Med/Low/Quiet) Motor Rating (HP) 0.04 Heat Exchanger Fin Type Blue Fin Weight (Ship/Net) 43.4/36.
Next Gen Arctic Series Submittal 18000 BTU/HR FLOOR CONSOLE INVERTER DRIVEN HEAT PUMP SYSTEM USYF18UCDWA 24 3/4 (630) 2 1/2 (65) 5/8 (16) 3/4 (20) 4 1/2 (115) 8 5/8 (220) 3/4 (20) 27 1/2 (700) 23 5/8 (600) 3 1/8 (80) 3 1/2 (90) 8 3/4 (223) ⑤ ② 7 1/8 (181) 3 1/2 (90) 3 1/8 (80) ③ ④ ② 26 1/8 (663) 25 1/8 (639) 16 (406) 3 1/4 (84) 3 1/4 (84) ⑦ ⑦ 5 7/8 (150) 21 1/8 (535) 9 7/8 (252) 19 3/8 (492) 9 (228) 5 3/4 (145) ⑥ # 1 2 3 4 5 6 7 Description Screw holes for floor install Side knockou
Next Gen Arctic Series Submittal 18000 BTU/HR MID-STATIC DUCTED INVERTER DRIVEN HEAT PUMP SYSTEM 1U18EH2VHE / USYM18UCDSA Job Name:___________________________________ Approval:____________________________________ Purchaser:___________________________________ Date: _______________________________________ Submitted To: ________________________________ Submitted By: ________________________________ Construction: ________________________________ Unit: ________________________________________ Reference:
Next Gen Arctic Series Submittal 18000 BTU/HR MID-STATIC DUCTED INVERTER DRIVEN HEAT PUMP SYSTEM 1U18EH2VHE / USYM18UCDSA Outdoor Unit Indoor Unit Compressor DC inverter Driven Rotary 30 x 36 1/4 x 15 1/8 in Uncrated Dimension (HxWxD) (762 x 920 x 385 mm) 34 x 42 3/4 x 19 1/8 in Crated (HxWxD) (863 x 1085 x 487 mm) Outdoor Sound Rating dB 52 Heat Exchanger Fin Type Blue Fin Weight (Ship/Net) 154.3/133.4 lbs Factory Refrigerant Charge R-410A (82.
Next Gen Arctic Series Submittal 18000 BTU/HR MID-STATIC DUCTED INVERTER DRIVEN HEAT PUMP SYSTEM ① ⑤ 15 3/4 (400) ⑥ 1 (25) Air flow 1 1/8 (30) 6 1/2 (166) ④ ③ ② 1 3/8 (35) 1 3/4 (44) 9 3/8 (238) 12 1/2 (317) 7 5/8 (195) 3 7/8 (100) ⑦ 9 3/4 (248) 6 1/4 (158) 5 (128) USYM18UCDSA Reversable fresh air supply adapter 27 1/2 (700) 24 3/8 (620.