Spec Sheet

60 31-5000409 Rev. 0
ESPAÑOL
SISTEMA
AW07LC2VHB AW09LC2VHB AW12LC2VHB AW18LC2VHB AW24LP2VHA
Capacidad de enfriamiento
nominal Btu/hr
7,000 9,000 12,000 18,000 22,000
capacidad de calefacción
nominal Btu/hr
8,000 10,000 13,000 19,000 24,000
Voltaje, Cicle, Etapa V/Hz/-
208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1
Flujo de aire CFM (Turbo/H/
M/L/Quiet)
410/350/295/235/205 410/350/295/235/205 440/380/320/265/215 636/530/483/430/383 710/650/560/440/410
Sonido interior dB (Turbo/H/
M/L/Quiet)
43/38/33/26/22 43/38/33/26/22 44/39/34/27/23 48/45/40/35/30 49/47/42/36/34
Dimensión: H x W x D in (mm)
11 x 33 5/8 x 8 1/16 (280 x 855 x 204) 12 3/4 x 39 1/4 x 9 1/4
(332 x 997 x 235)
13 1/4 x 43 7/8 x 9 9/16
(336 x 1115 x 243)
Peso (Envío/ Neto) – lbs. (kg.)
26.8/22(12.2/10) 35.3/28.6 (16/13) 45.4/37.5 (20.6/17)
Liquido /Succión O.D. in
1/4 3/8 1/4 3/8 1/4 3/8 1/4 1/2 3/8 5/8
AD07SL2VHB AD09SL2VHB AD12SL2VHB AD18SL2VHB AM24LP2VHA
Capacidad de enfriamiento
nominal Btu/hr
7,000 9,000 12,000 18,000 24,000
capacidad de calefacción nominal
Btu/hr
8,000 10,000 13,000 19,000 27,000
Voltaje, Cicle, Etapa V/Hz/-
208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1
Flujo de aire CFM (Turbo/H/M/L/
Quiet)
353/312/270/230/188 353/312/270/230/188 400/353/282/247/218 540/500/447/365/306 845/670/530/470
Máx. Presión Estática Ext. en
pulgadas por columna de agua
(Pa)
0.16 (40) 0.16 (40) 0.16 (40) 0.16 (40) 0.6 (150)
Indoor Sound dB (Turbo/H/M/L/
Quiet)
35/33/29/26/21 35/33/29/26/22 38/35/29/26/23 31/29/23/29/25 38/35/32/29
Dimension: HxWxD in (mm)
7 5/16 x 33 7/16 x16 9/16(185x850x420) 7 5/16 x 46 1/16 x16 9/16
(185x1170x420)
9 7/8 x 37 5/8 x 25 3/4
(250x957x655)
Peso (Envío/ Neto) – lbs. (kg.)
47.2/36.8 (21.4/16.7) 47.2/36.8 (21.4/16.7) 47.2/36.8 (21.4/16.7) 61.8/48.5(28/22) 68.8/81.1 (31.2/36.8)
Liquido /Succión O.D. in
1/4 3/8 1/4 3/8 1/4 3/8 1/4 1/2 3/8 5/8
tamaño de la tubería de drenaje
O.D. in
1 1/4 1 1/4 1 1/4 1 1/4 1 1/4
Condensate Pump
Standard Standard Standard Standard Standard
Máx. Elevación de Desagüe en
pulg. (mm)
27 9/16 (700) 27 9/16 (700) 27 9/16 (700) 27 9/16 (700) 27 9/16 (700)
AB09SC2VHA AB12SC2VHA AB18SC2VHA AL24LP2VHA
Capacidad de enfriamiento nominal Btu/hr
9,000 12,000 18,000 24,200
capacidad de calefacción nominal Btu/hr
10,000 13,000 19,000 27,300
Voltaje, Cicle, Etapa V/Hz/-
208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1
Flujo de aire CFM (Turbo/H/M/L/Quiet)
410/365/305/265/205 410/365/305/265/205 470/410/365/295/252 740/630/480/400
Máx. Presión Estática Ext. en pulgadas por
columna de agua (Pa)
42/40/36/32/25 42/40/36/32/25 45/42/40/36/32 38/35/32/29
Modelo con Rejilla
PB-700IB PB-700IB PB-700IB PB-950KB
Chassis Dimension: HxWxD in (mm)
10 1/4 x 22 7/16 x 2 3/8 (260 x 570 x 570) 9 5/8 x 33 1/8 x 33 1/8 (246 x 840 x840)
Tamaño de la Rejilla: Altura x Ancho x Diámetro
en pulg. (mm)
2 3/8 x 27 9/16 x 27 9/16 (60 x 700 x 700) 2 x 3 1/8 x 3 1/8 (50 x 950 x 950)
Peso (Envío/ Neto) – lbs. (kg.)
46.3/37.5 (21/17) 68.4/79.4 (31/36)
Liquido /Succión O.D. in
1/4 3/8 1/4 3/8 1/4 1/2 3/8 5/8
tamaño de la tubería de drenaje O.D. in
1 1/4 1 1/4 1 1/4 1
Bomba de Condensación Interna
Standard Standard Standard Standard
Máx. Elevación de Desagüe en pulg. (mm)
27 9/16 (700) 27 9/16 (700) 27 9/16 (700) 47 1/4(1200)
Unidades Interiores de Pared Alta
Unidades Interiores con Conducto
Unidades Interiores Tipo Cassette