Submittals

Arctic Multi Series Submittal
Rev. May 2020
Cooling Capacity Data - Ducted
Outdoor
Air Temp
DB
Indoor Set Temperature
70
O
F (21
O
C) 75
O
F (24
O
C) 80
O
F (27
O
C)
Total Capacity
(Btu/h)
Power Usage
(w)
Total Capacity
(Btu/h)
Power Usage
(w)
Total Capacity
(Btu/h)
Power Usage
(w)
14
O
F (-10
O
C) 23,500 2,320 24,980 2,320 25,440 2,360
65
O
F (18
O
C) 35,980 2,460 36,200 2,630 37,420 2,690
75
O
F (24
O
C) 33,960 2,790 34,980 2,830 36,200 2,950
85
O
F (29
O
C) 33,780 2,850 34,780 2,930 35,400 2,950
95
O
F (35
O
C) 35,900 3,320 35,700 3,340 34,200 3,420
105
O
F (41
O
C) 31,600 3,420 32,800 3,430 33,700 3,520
115
O
F (46
O
C) 27,420 3,770 28,920 3,820 29,900 3,900
Heating Capacity Data - Non Ducted
Outdoor
Air Temp
DB
Indoor Set Temperature
60
O
F (16
O
C) 70
O
F (21
O
C) 77
O
F (25
O
C)
Maximum Heating
Capacity (Btu/h)
Power Usage
(w)
Max Heating
Capacity (Btu/h)
Power Usage
(w)
Max Heating
Capacity (Btu/h)
Power Usage
(w)
-15
O
F (-26
O
C) 25,900 4,960 25,700 5,010 25,000 5,020
-4
O
F (-20
O
C) 30,100 4,970 29,800 5,040 28,200 5,060
5
O
F (-15
O
C) 36,200 4,980 36,000 5,270 35,100 5,300
17
O
F (-8
O
C) 38,500 3,940 37,000 3,950 36,500 4,200
47
O
F (8
O
C) 38,900 3,100 38,000 3,190 37,800 3,200
Heating Capacity Data - Ducted
Outdoor
Air Temp
DB
Indoor Set Temperature
60
O
F (16
O
C) 70
O
F (21
O
C) 77
O
F (25
O
C)
Maximum Heating
Capacity (Btu/h)
Power Usage
(w)
Max Heating
Capacity (Btu/h)
Power Usage
(w)
Max Heating
Capacity (Btu/h)
Power Usage
(w)
-15
O
F (-26
O
C) 25,500 5,100 25,000 5,200 24,500 5,430
-4
O
F (-20
O
C) 29,700 5,200 29,000 5,400 28,100 5,490
5
O
F (-15
O
C) 35,800 5,300 35,000 5,480 34,600 5,560
17
O
F (-8
O
C) 36,600 4,010 36,000 4,030 35,700 4,760
47
O
F (8
O
C) 36,300 3,310 37,000 3,180 35,900 3,760
Cooling Capacity Data - Non Ducted
Outdoor
Air Temp
DB
Indoor Set Temperature
70
O
F (21
O
C) 75
O
F (24
O
C) 80
O
F (27
O
C)
Total Capacity
(Btu/h)
Power Usage
(w)
Total Capacity
(Btu/h)
Power Usage
(w)
Total Capacity
(Btu/h)
Power Usage
(w)
14
O
F (-10
O
C) 23,300 1,900 24,070 1,920 25,330 1,960
65
O
F (18
O
C) 34,780 2,180 35,980 2,230 37,340 2,290
75
O
F (24
O
C) 33,560 2,390 34,870 2,410 36,120 2,450
85
O
F (29
O
C) 33,380 2,440 34,650 2,520 35,300 2,550
95
O
F (35
O
C) 35,500 2,950 35,600 2,970 35,700 2,980
105
O
F (41
O
C) 31,210 3,010 32,600 3,020 33,650 3,120
115
O
F (46
O
C) 26,980 3,370 28,230 3,400 29,700 3,500
36000 BTU/HR INVERTER DRIVEN MULTI-ZONE HEAT PUMP SYSTEM
4U36EH2VHA
Capacity output and power usage are measured approximately at 50% indoor RH.
Capacities are obtained at standard piping length of each outdoor model
Specications are subject to change without notice. © 2019 GE Appliances, a Haier Company All rights reserved