Submittals

Arctic Multi Series Submittal
Rev. May 2020
20000 BTU/HR INVERTER DRIVEN MULTI-ZONE HEAT PUMP SYSTEM
2U20EH2VHA
Heating Capacity Data - Non Ducted
Outdoor
Air Temp
DB
Indoor Set Temperature
60
O
F (16
O
C) 70
O
F (21
O
C) 77
O
F (25
O
C)
Maximum Heating
Capacity (Btu/h)
Power Usage
(w)
Max Heating
Capacity (Btu/h)
Power Usage
(w)
Max Heating
Capacity (Btu/h)
Power Usage
(w)
-15
O
F (-26
O
C) 19,320 2,920 17,250 3,190 16,200 3,330
-4
O
F (-20
O
C) 23,150 3,010 20,060 3,290 16,700 3,420
5
O
F (-15
O
C) 25,600 3,110 23,500 3,350 21,200 3,670
17
O
F (-8
O
C) 27,100 3,120 25,360 3,560 22,650 3,730
47
O
F (8
O
C) 29,470 3,350 27,890 3,780 25,170 4,030
Heating Capacity Data - Ducted
Outdoor
Air Temp
DB
Indoor Set Temperature
60
O
F (16
O
C) 70
O
F (21
O
C) 77
O
F (25
O
C)
Maximum Heating
Capacity (Btu/h)
Power Usage
(w)
Max Heating
Capacity (Btu/h)
Power Usage
(w)
Max Heating
Capacity (Btu/h)
Power Usage
(w)
-15
O
F (-26
O
C) 17,880 3,160 16,310 3,220 15,260 3,280
-4
O
F (-20
O
C) 19,930 3,260 18,690 3,310 15,830 3,320
5
O
F (-15
O
C) 21,850 3,320 21,000 3,380 19,210 3,710
17
O
F (-8
O
C) 25,310 3,560 24,340 3,610 21,030 3,760
47
O
F (8
O
C) 26,860 3,680 25,890 3,820 23,460 4,130
Cooling Capacity Data - Non Ducted
Outdoor
Air Temp
DB
Indoor Set Temperature
70
O
F (21
O
C) 75
O
F (24
O
C) 80
O
F (27
O
C)
Total Capacity
(Btu/h)
Power Usage
(w)
Total Capacity
(Btu/h)
Power Usage
(w)
Total Capacity
(Btu/h)
Power Usage
(w)
14
O
F (-10
O
C) 7,560 720 9,160 810 10,320 890
65
O
F (18
O
C) 17,840 980 19,560 1,040 20,520 1,070
75
O
F (24
O
C) 16,630 990 19,010 1,110 20,030 1,150
85
O
F (29
O
C) 15,260 1,020 18,690 1,230 19,670 1,290
95
O
F (35
O
C) 15,091 1,260 18,230 1,430 19,020 1,466
105
O
F (41
O
C) 14,860 1,390 16,510 1,490 17,830 1,590
115
O
F (46
O
C) 11,580 1,250 14,870 1,540 15,856 1,620
Cooling Capacity Data - Ducted
Outdoor
Air Temp
DB
Indoor Set Temperature
70
O
F (21
O
C) 75
O
F (24
O
C) 80
O
F (27
O
C)
Total Capacity
(Btu/h)
Power Usage
(w)
Total Capacity
(Btu/h)
Power Usage
(w)
Total Capacity
(Btu/h)
Power Usage
(w)
14
O
F (-10
O
C) 6,370 750 7,020 810 7,500 830
65
O
F (18
O
C) 16,210 1,350 19,120 1,550 20,130 1,580
75
O
F (24
O
C) 15,100 1,620 18,760 1,690 19,940 1,720
85
O
F (29
O
C) 14,950 1,660 17,800 1,780 19,150 1,810
95
O
F (35
O
C) 14,680 1,630 16,420 1,790 18,780 1,860
105
O
F (41
O
C) 13,360 1,730 15,690 1,870 17,490 2,040
115
O
F (46
O
C) 10,200 1,450 13,860 1,810 15,700 2,190
Capacity output and power usage are measured approximately at 50% indoor RH.
Capacities are obtained at standard piping length of each outdoor model
Specications are subject to change without notice. © 2019 GE Appliances, a Haier Company All rights reserved