Submittals

FlexFit Multi Series Submittal
Rev. Mar. 2021
Cooling Capacity Data - Ducted
Outdoor
Air Temp
DB
Indoor Set Temperature
70
O
F (21
O
C) 75
O
F (24
O
C) 80
O
F (27
O
C)
Total Capacity
(Btu/h)
Power Usage
(w)
Total Capacity
(Btu/h)
Power Usage
(w)
Total Capacity
(Btu/h)
Power Usage
(w)
14
O
F (-10
O
C) 18,670 1,140 20,110 1,180 21,680 1,220
65
O
F (18
O
C) 24,300 1,790 27,100 1,960 28,560 2,010
75
O
F (24
O
C) 25,130 1,920 25,800 2,030 26,300 2,100
85
O
F (29
O
C) 25,880 2,250 24,150 2,320 24,900 2,360
95
O
F (35
O
C) 22,960 2,480 25,200 2,820 26,460 2,890
105
O
F (41
O
C) 20,530 2,300 22,170 2,760 22,690 2,650
115
O
F (46
O
C) 16,250 1,820 17,850 2,150 18,560 2,400
24000 BTU/HR INVERTER DRIVEN MULTI-ZONE HEAT PUMP SYSTEM
3U24MS2VHB
Capacity and power usage are measured under the assumption of indoor humidity of 46%
Capacity and power usage are measured under the assumption of indoor humidity of 46%
Heating Capacity Data - Non Ducted
Outdoor
Air Temp
DB
Indoor Set Temperature
60
O
F (16
O
C) 70
O
F (21
O
C) 77
O
F (25
O
C)
Maximum Heating
Capacity (Btu/h)
Power Usage
(w)
Max Heating
Capacity (Btu/h)
Power Usage
(w)
Max Heating
Capacity (Btu/h)
Power Usage
(w)
-4
O
F (-20
O
C) 15,660 1,890 13,500 1,960 12,370 2,080
5
O
F (-15
O
C) 15,980 1,810 14,960 1,900 12,570 1,920
17
O
F (-8
O
C) 17,790 1,940 17,720 1,970 14,650 1,980
47
O
F (8
O
C) 27,400 2,150 25,600 2,350 22,860 2,440
Heating Capacity Data - Ducted
Outdoor
Air Temp
DB
Indoor Set Temperature
60
O
F (16
O
C) 70
O
F (21
O
C) 77
O
F (25
O
C)
Maximum Heating
Capacity (Btu/h)
Power Usage
(w)
Max Heating
Capacity (Btu/h)
Power Usage
(w)
Max Heating
Capacity (Btu/h)
Power Usage
(w)
-4
O
F (-20
O
C) 12,760 1,650 11,000 1,670 10,120 1,790
5
O
F (-15
O
C) 15,500 1,940 15,290 2,020 10,280 1,850
17
O
F (-8
O
C) 17,630 1,900 17,360 2,070 13,100 1,920
47
O
F (8
O
C) 26,200 2,050 24,580 2,180 22,300 2,300
Cooling Capacity Data - Non Ducted
Outdoor
Air Temp
DB
Indoor Set Temperature
70
O
F (21
O
C) 75
O
F (24
O
C) 80
O
F (27
O
C)
Total Capacity
(Btu/h)
Power Usage
(w)
Total Capacity
(Btu/h)
Power Usage
(w)
Total Capacity
(Btu/h)
Power Usage
(w)
14
O
F (-10
O
C) 19,200 1,080 20,430 1,120 21,700 1,190
65
O
F (18
O
C) 25,980 1,860 28,640 2,150 30,480 2,260
75
O
F (24
O
C) 26,510 2,100 27,530 2,460 28,690 2,650
85
O
F (29
O
C) 25,950 2,230 26,180 2,580 27,430 2,740
95
O
F (35
O
C) 23,520 2,500 25,360 2,880 26,700 3,000
105
O
F (41
O
C) 20,860 2,350 22,270 2,760 23,560 2,850
115
O
F (46
O
C) 16,890 1,860 17,950 2,150 18,680 2,350