Submittals FlexFit Pro Single Series Rev. Sept. 2020 1U24LP2VHA / AW24LP2VHA 1U24LP2VHA / AM24LP2VHA 1U24LP2VHA / AL24LP2VHA 1U36LP2VHA / AW36LP2VHA 1U36LP2VHA / AM36LP2VHA 1U36LP2VHA / AL36LP2VHA 1U48LP2VHA / AM48LP2VHA 1U48LP2VHA / AL48LP2VHA C For more information visit us: www.Haierductless.com www.Haierductlesshelp.
Revision History Rev. April 2017 - Edition release Rev. May 2017 - AM24LP2VHA dimension diagram correction; AL48LP2VHA cooling capacity correction. Rev. April 2018 - Added Motor Ratings (all models), Condensate Pump Lift (AM24LP2VHA, AM36LP2VHA, AM48LP2VHA, AL24LP2VHA, AL36LP2VHA, AL48LP2VHA); Maximum ESP (AM24LP2VHA, AM36LP2VHA, AM48LP2VHA); Dimension diagram updates (AM24LP2VHA, AL models). Rev.
FlexFit Pro Single Submittal 24000 BTU/HR WALL MOUNTED INVERTER DRIVEN HEAT PUMP SYSTEM 1U24LP2VHA / AW24LP2VHA Job Name:___________________________________ Approval:____________________________________ Purchaser:___________________________________ Date: _______________________________________ Submitted To: ________________________________ Submitted By: ________________________________ Construction: ________________________________ Unit: ________________________________________ Reference:__________
FlexFit Pro Single Submittal 24000 BTU/HR WALL MOUNTED INVERTER DRIVEN HEAT PUMP SYSTEM 1U24LP2VHA / AW24LP2VHA Indoor Unit Outdoor Unit 14 3/8 x 43 7/8 x 9 5/8 in (366 x 1115 x 243 mm) 16 1/2 x 47 1/2 x 13 1/2 in Crated (HxWxD) (418 x 1206 x 342 mm) Airflow CFM 710/650/560/440/410 (Turbo/High/Med/Low/Quiet) Indoor Sound Level dB 49/47/42/36/34 (Turbo/High/Med/Low/Quiet) Motor Rating (HP) 0.094 Heat Exchanger Fin Type Blue Fin Weight (Ship/Net) 45.4/37.
FlexFit Pro Single Submittal 24000 BTU/HR HIGH STATIC DUCTED INDOOR INVERTER DRIVEN HEAT PUMP SYSTEM 1U24LP2VHA / AM24LP2VHA Job Name:___________________________________ Approval:____________________________________ Purchaser:___________________________________ Date: _______________________________________ Submitted To: ________________________________ Submitted By: ________________________________ Construction: ________________________________ Unit: ________________________________________ Referen
FlexFit Pro Single Submittal 24000 BTU/HR HIGH STATIC DUCTED INDOOR INVERTER DRIVEN HEAT PUMP SYSTEM 1U24LP2VHA / AM24LP2VHA Indoor Unit Outdoor Unit 7/8 x 41 3/8 x 28 3/8 in Uncrated Dimension (HxWxD) 9 (250 x 1050 x 720 mm) 3/8 x 46 1/8 x 33 7/8 in Crated (HxWxD) 13 (340 x 1170 x 860 mm) Maximum ESP (IWC) 0.60 Airflow CFM (Turbo/High/Med/Low/Quiet) 845/670/530/470 Indoor Sound Level dB (Turbo/High/Med/Low/Quiet) 38/35/32/29 Motor Rating (HP) 0.
FlexFit Pro Single Submittal 24000 BTU/HR 3x3 LARGE CASSETTE INVERTER DRIVEN HEAT PUMP SYSTEM 1U24LP2VHA / AL24LP2VHA Job Name:___________________________________ Approval:____________________________________ Purchaser:___________________________________ Date: _______________________________________ Submitted To: ________________________________ Submitted By: ________________________________ Construction: ________________________________ Unit: ________________________________________ Reference:____
FlexFit Pro Single Submittal 24000 BTU/HR 3x3 LARGE CASSETTE INVERTER DRIVEN HEAT PUMP SYSTEM 1U24LP2VHA / AL24LP2VHA Indoor Unit Outdoor Unit 5/8 x 33 1/8 x 33 1/8 in Uncrated Dimension (HxWxD) 9 (246 x 840 x 840 mm) 1/4 x 39 x 39 in Crated (HxWxD) 12 (310 x 990 x 990 mm) x 37 3/8 x 37 3/8 in Panel Uncrated Dimension (HxWxD) 2 (50 x 950 x 950 mm) 3/8 x 39 3/8 x 39 3/8 in Panel Crated (HxWxD) 4 (110 x 1000 x 1000 mm) Airflow CFM (Turbo/High/Med/Low/Quiet) 740/630/480/400 Indoor Sound Level dB (Turbo/High
FlexFit Pro Single Submittal 36000 BTU/HR WALL MOUNTED INVERTER DRIVEN HEAT PUMP SYSTEM 1U36LP2VHA / AW36LP2VHA Job Name:___________________________________ Approval:____________________________________ Purchaser:___________________________________ Date: _______________________________________ Submitted To: ________________________________ Submitted By: ________________________________ Construction: ________________________________ Unit: ________________________________________ Reference:__________
FlexFit Pro Single Submittal 36000 BTU/HR WALL MOUNTED INVERTER DRIVEN HEAT PUMP SYSTEM 1U36LP2VHA / AW36LP2VHA Indoor Unit Outdoor Unit 14 3/8 x 51 3/4 x 10 7/8 in (365 x 1316 x 275 mm) 18 7/8 x 55 7/8 x 15 7/8 in Crated (HxWxD) (478 x 1418 x 402 mm) Airflow CFM 720/660/570/450/420 (Turbo/High/Med/Low/Quiet) Indoor Sound Level dB (Turbo/High/Med/Low/Quiet) 50/48/44/38/36 Motor Rating (HP) 0.094 Heat Exchanger Fin Type Blue Fin Weight (Ship/Net) 55.1/46.
FlexFit Pro Single Submittal 36000 BTU/HR HIGH STATIC DUCTED INDOOR INVERTER DRIVEN HEAT PUMP SYSTEM 1U36LP2VHA / AM36LP2VHA Job Name:___________________________________ Approval:____________________________________ Purchaser:___________________________________ Date: _______________________________________ Submitted To: ________________________________ Submitted By: ________________________________ Construction: ________________________________ Unit: ________________________________________ Referen
FlexFit Pro Single Submittal 36000 BTU/HR HIGH STATIC DUCTED INDOOR INVERTER DRIVEN HEAT PUMP SYSTEM 1U36LP2VHA / AM36LP2VHA Indoor Unit Outdoor Unit 7/8 x 59 x 28 3/8 in Uncrated Dimension (HxWxD) 9 (250 x 1500 x 720 mm) 5/8 x 67 3/8 x 34 in Crated (HxWxD) 12 (320 x 1710 x 865 mm) Maximum ESP (IWC) 0.60 Airflow CFM (Turbo/High/Med/Low/Quiet) 1100/950/735/675 Indoor Sound Level dB (Turbo/High/Med/Low/Quiet) 32/28/25/23 Motor Rating (HP) 0.
FlexFit Pro Single Submittal 36000 BTU/HR 3x3 LARGE CASSETTE INVERTER DRIVEN HEAT PUMP SYSTEM 1U36LP2VHA / AL36LP2VHA Job Name:___________________________________ Approval:____________________________________ Purchaser:___________________________________ Date: _______________________________________ Submitted To: ________________________________ Submitted By: ________________________________ Construction: ________________________________ Unit: ________________________________________ Reference:____
FlexFit Pro Single Submittal 36000 BTU/HR 3x3 LARGE CASSETTE INVERTER DRIVEN HEAT PUMP SYSTEM 1U36LP2VHA / AL36LP2VHA Indoor Unit Outdoor Unit 5/8 x 33 1/8 x 33 1/8 in Uncrated Dimension (HxWxD) 9 (246 x 840 x 840 mm) 1/4 x 39 x 39 in Crated (HxWxD) 12 (310 x 990 x 990 mm) x 37 3/8 x 37 3/8 in Panel Uncrated Dimension (HxWxD) 2 (50 x 950 x 950 mm) 3/8 x 39 3/8 x 39 3/8 in Panel Crated (HxWxD) 4 (110 x 1000 x 1000 mm) Airflow CFM (Turbo/High/Med/Low/Quiet) 740/630/480/400 Indoor Sound Level dB (Turbo/High
FlexFit Pro Single Submittal 48000 BTU/HR HIGH STATIC DUCTED INDOOR INVERTER DRIVEN HEAT PUMP SYSTEM 1U48LP2VHA / AM48LP2VHA Job Name:___________________________________ Approval:____________________________________ Purchaser:___________________________________ Date: _______________________________________ Submitted To: ________________________________ Submitted By: ________________________________ Construction: ________________________________ Unit: ________________________________________ Referen
FlexFit Pro Single Submittal 48000 BTU/HR HIGH STATIC DUCTED INDOOR INVERTER DRIVEN HEAT PUMP SYSTEM 1U48LP2VHA / AM48LP2VHA Indoor Unit Outdoor Unit 7/8 x 59 x 28 3/8 in Uncrated Dimension (HxWxD) 9 (250 x 1500 x 720 mm) 3/8 x 63 3/4 x 33 7/8 in Crated (HxWxD) 13 (340 x 1620 x 860 mm) Maximum ESP (IWC) 0.60 Airflow CFM (Turbo/High/Med/Low/Quiet) 1350/1150/930/765 Indoor Sound Level dB (Turbo/High/Med/Low/Quiet) 41/36/33/31 Motor Rating (HP) 0.
FlexFit Pro Single Submittal 48000 BTU/HR 3x3 LARGE CASSETTE INVERTER DRIVEN HEAT PUMP SYSTEM 1U48LP2VHA / AL48LP2VHA Job Name:___________________________________ Approval:____________________________________ Purchaser:___________________________________ Date: _______________________________________ Submitted To: ________________________________ Submitted By: ________________________________ Construction: ________________________________ Unit: ________________________________________ Reference:____
FlexFit Pro Single Submittal 48000 BTU/HR 3x3 LARGE CASSETTE INVERTER DRIVEN HEAT PUMP SYSTEM 1U48LP2VHA / AL48LP2VHA Indoor Unit Outdoor Unit 3/8 x 33 1/8 x 33 1/8 in Uncrated Dimension (HxWxD) 11 (288 x 840 x 840 mm) x 39 x 39 in Crated (HxWxD) 15 (380 x 990 x 990 mm) x 37 3/8 x 37 3/8 in Panel Uncrated Dimension (HxWxD) 2 (50 x 950 x 950 mm) 3/8 x 39 3/8 x 39 3/8 in Panel Crated (HxWxD) 4 (110 x 1000 x 1000 mm) Airflow CFM (Turbo/High/Med/Low/Quiet) 740/630/480/400 Indoor Sound Level dB (Turbo/High/Me