Installation guide

INSTALLATION
PAGE 5
ENGLISH
Outdoor Unit Clearances
Step 1 - Preparation
more than 8 in.
more than 6 in.
more than 4 in.
more than 4 in.
more than 24 in.
more than 10 in.
Required Tools for Installation Procedure for Selecting the Location
 Drill
 Wire Snipper
 Hole Saw 2 3/4”
 Vacuum pump
 Soap-and-water solution or gas leakage
detector
 Torque wrench
 17mm, 22mm, 26mm
 Tubing cutter
 Flaring tool
 Razor knife
 Measuring tape
 Level
 Micron gauge
 Nitrogen
 Mini-Split AD-87 Adapter (1/4” to 5/16”)
 A - Non-adhesive Tape
 B - Adhesive Tape
 C - Saddle (L.S.) with screws
 D - Electrical wiring
 E - Drain hose (Included)
 F - Insulation
 G - Piping hole cover (Included)
more than 10ft away depending on radio
wave conditions.)
 
do not place anything under the unit that
must be kept away from moisture.
Note:
1) Cannot be installed hanging from ceiling
or stacked.
2) If installing on a high place such as a roof,
with a fence or guard rail around it.
3) If there is a potential for accumulated
snow to block the air inlet or heat ex-
changer, install the unit on a higher base.
4) R-410A refrigerant is a safe, nontoxic and

there is a concern about a dangerous level
of refrigerant concentration in the case of
refrigerant leakage, add extra ventilation.
5) Avoid installing the outdoor unit where
corrosive gases, such as sulfur oxides, am-
monia, and sulfurous gas, are produced. If
unavoidable, consult with an installation
specialist about using a corrosion-proof or
anti-rust additive to protect the unit coils.
 Choose a place solid enough to bear
the weight and vibration of the unit and
where the operation noise will not be

 Choose a location where the hot air
discharged from the unit or the operation
noise and will not cause a nuisance to the
neighbors of the user.
 
carrying the unit into and out of the site.
 
passage and no obstructions around the
air inlet and air outlet.
 The site must be free from the possibility

place.
 Locate the unit to avoid noise and
discharged hot air will not annoy the
neighbors.
 Install units, power cords and inter-unit
cables at least 10ft away from television
and radio sets. This is to prevent
interference to images and sounds.
(Noise may be heard even if they are