6.4.3 Heating discharge pressure curves
HSU-09HSA03/R2(DB)
Heating discharge pressure table
Outdoor temp. (Humidity 46%) Indoor temp.
DB/WB
15ć 20ć 25ć
ˉ15ć 2109 2226 2400
ˉ10ć 2155 2277 2454
ˉ5ć 2256 2467 2600
0ć 2430 2615 2734
5ć 2527 2697 2851
10ć 2595 2779 2952
15ć 2631 2815 3036
20ć 2743 2945 3145