DUCT TYPE AIR CONDITIONING Operation & Installation Manual AD092AMBHA AU092AABHA (HDU-09HA03/M(R1)(B)) AD122AMBHA AU122AABHA (HDU-12HA03/M(R1)(B)) No.
TABLE OF CONTENTS 2 CAUTIONS 3-5 SAFETY PRECAUTIONS PARTS AND FUNCTIONS 6 MALFUNCTION 7-8 CARE AND MAINTENANCE 9-10 INSTALLATION MANUAL FOR OUTDOOR UNIT 11-14 INSTALLATION MANUAL FOR INDOOR UNIT 15-20 INSTALLATION MANUAL FOR ELECTRIC WIRING 21 INSTALLATION MANUAL FOR WIRE CONTROLLER 22 CHECK AND TEST RUN 23 1
CAUTIONS Disposal of the old air conditioner Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment. It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in a air conditioner can be recycled.
SAFETY PRECAUTIONS Before starting to use the system, read carefully this"SAFETY PRECAUTIONS" to ensure a proper operation of the system. Safety precautions described here are classified to " WARNING" and " CAUTION". Precautions which are shown in the column of " WANING" means that an improper handing could lead to a grave result like a death, serious injury, etc. However, even if precautions are shown in the column of " CAUTION", a very serious problem could occur depending on situation.
SAFETY PRECAUTIONS CAUTION Do not wash the air conditioner with water. It could cause electric shocks. Neither stand on the air conditioner nor place something on it. Do not install the system where the air outlet reaches directly the flora and fauna. Make sure to use a fuse of proper electric rating. It will not be good for their health. Use of steel or copper wire in place of a fuse is strictly prohibited because it could result in a trouble or fire accident.
SAFETY PRECAUTIONS The machine is adaptive in following situation 1. Applicable ambient temperature range: Indoor Maximum:D.B / W.B 32 C/ 23 C Minimum: D.B / W. 18 C/ 14 C Outdoor Maximum: D.B Minimum: D.B 43 C/ 26 C 15 C Indoor Maximum: D.B Minimum: D.B 27 C 20 C Outdoor Maximum: D.B / W.B 24 C/ 18 C Minimum: D.B / W.B -7 C/ -8 C Cooling Heating 2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.
PARTS AND FUNCTIONS Indoor Unit Fan(inside) Motor(inside) Outdoor Unit Air inlet Connecting piping and electrical wiring Drain hose Air outlet 6
MALFUNCTION please check the following things about your air conditioner before making a servie call. Unit fails to start Is city supply power in normal? Is the power source switch adjust cut in? Isn't the signal receiving Isn't the earth leakage section exposed to the breaker in action? direct sunlight or strong illumination? It is dangerous. Turn off the power supply switch immediately and contact the sales dealer. ON Power stoppage? OFF Power supply switch is not ON.
MALFUNCTION The followings are not malfunction Water flowing sound is heard. Sh Sh uru ur u When the air conditioner is started, when the compressor starts or stops during operation or when the air conditioner is stopped, it sometimes sounds "shuru shuru" or "gobo gobo". It is the flowing sound of the refrigerant, and it is not a trouble. Cracking sound is heard. This is caused by heat expansion or contraction of plastics. It smells. Air which blows out from the indoor unit sometimes smells.
CARE AND MAINTENANCE Points to observe Turn off the power supply switch. Do not touch with wet hand. Do not use hot water or volatileliquid. ON Thinner Do not use! Benzine Tooth powder OFF CAUTION Do not open the inlet grill until fan stops completely. Fan will continue rotating for a while by the law of inertia after operation is being stopped. Cleaning 1. Clean the air filter by lightly tapping it or with the cleaner. It is more effective to clean the air filter with water.
CARE AND MAINTENANCE "HOT KEEP"is operated in the following cases. When heating is started: In order to prevent blowing out of cool wind, the indoor unit fan stopped according to the room temperature which heating operation is started. Wait for approx. 2 to 3 minute, and the operation will be automatically changed to the ordinary heating mode. Defrosting operation (in the heating mode): When it is liable to frost. the heating operation is stopped automatically for 5 to 12 minutes once per approx.
INSTALLATION MANUAL FOR OUTDOOR UNIT Confirm the following items for safe and comfortable use of air conditioner. The installation work is to be burden on the sales dealer, and do not conduct it by yourself. Installation place Avoid installing the air conditioner Install the unit at well ventilated near the place where possibility of place. inflammable gas leakage exists. Install the air conditioner firmly on the foundation that can fully support the weight of the unit.
INSTALLATION MANUAL FOR OUTDOOR UNIT WARNING BE SURE TO READ THESE INSTRUCTIONS CAREFULLY BEFORE BEGINNING INSTALLATION. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD CAUSE SERIOUS INJURY OR DEATH, EQUIPMENT MALFUNCTION AND/OR PROPERTY DAMAGE. BE SURE TO READ INSTALLATION MANUAL FOR INDOOR UNIT WITH THIS MANUAL. 1. Accessories Edging "Edging" for protection of electric wires from an opening edge. 2.
INSTALLATION MANUAL FOR OUTDOOR UNIT 4. Refrigerant piping (1) Outline piping Flare connection 3-way valve Liquid pipe Outdoor Indoor unit unit 3-way valve Gas pipe Flare connection Gas piping 12.7(1/2")x1.0mm Liquid piping 6.35(1/4")x0.8mm Install the removed flared nuts to the pipes to be connected, then flare the pipes. 90 + 0.5 (2) Piping size (3) Limitations for one way piping length and vertical height One way piping length: less than 15m.
INSTALLATION MANUAL FOR OUTDOOR UNIT (5) Purging method ( the refrigerant is R407C) Liquid pipe 6.35mm(1/4'') To use vacuum pump Gas pipe 1 12.7mm(1/2'') Detach the service port's cap of 3-way valve, the 3-way valve 3-way valve valve rod's cap for 3-way valve and 3-way's, connect the service port into the projection of charge hose Gaugemanifold (low) for gaugemanifold. Then connect the projection of charge hose (center) for gaugemanifold into vacuum pump.
INSTALLATION MANUAL FOR INDOOR UNIT 1. Safety precautions Please read these "Safety Precautions" first then accurately execute the installation work. Though the precautionary points indicated herein are divided under two headings, WARNING and CAUTION , those points which are related to the strong possibility of an installation done in error resulting in death or serious injury are listed in the WARNING section.
INSTALLATION MANUAL FOR INDOOR UNIT NOTICE All Wiring of this installation must comply with NATIONAL, STATE AND LOCAL REGULATIONS. These instructions do not cover all variations for every kind of installation circumstance. Should further information be desired or should particular problems occur, the matter should be referred to your local distributor. WARNING BE SURE TO READ THESE INSTRUCTIONS CAREFULLY BEFORE BEGINNING INSTALLATION.
INSTALLATION MANUAL FOR INDOOR UNIT (4) Preparation for suspending the unit (a) Figure of installation dimension: (unit: mm) 450 830 225 220 80 125 no be thin d l i ou w sh s re cle e Th bsta o 0 25 When install the duct hidden type indoor unit, the return air box must be designed and installed, as Figure3, Figure4. The distance between the air outlet of duct and the air outlet of air conditioner should be no more than 0.5m. This duct type air conditioner is low static pressure model.
INSTALLATION MANUAL FOR INDOOR UNIT A amplified M8 wide expansion screw bolt M8 hoisting screw Unit M8 wide lock washer M8 screw nut 28 B Rivet (Figure 6) C Air supply passage B B amplified (Figure 5) C amplified B Top panel of unit Use screw to fix top panel Air supply passage Air outlet grille Install the hoisting screw* Use M8 or M10 hoisting screw (4, prepare on site) (When the height of hoisting screw is more than 0.
INSTALLATION MANUAL FOR INDOOR UNIT Original cement panel Use the in hole hinge, in hole plug or in hole screw. Steel structure Suspending bolt Directly use angle steel or new angle steel for support. Hoisting screw Suspending of indoor unit Angle steel for support Fix the cap of hoisting screw on and suspend them on the T groove of the hoisting part of the unit. Use gradienter to keep the level degree of the unit within 5mm.
INSTALLATION MANUAL FOR INDOOR UNIT Material of connection pipe and thermal insulation Material of connection pipe Stiff PVC pipe VP 20mm (inside diameter) Foam polyethylene pipe, thickness over 10mm Material of thermal insulation Confirm drainage Perform test run to insure the condition of drainage, the connection part of the connection should not leak water. The confirmation must be performed even if install in winter.
INSTALLATION MANUAL FOR ELECTRIC WIRING 5. Electric wiring Cautions: Use copper wire only.Parameters of connecting line : H05RN-F 4G0.75mm2 Power supply :1PH,220-230V~,50Hz, connect from outside. 1(L ) Wiring methods: 1.Wiring method of ring terminal For connecting line which end is a ring,its wiring method as shown in the right figure: remove wiring screw and pass it through the end ring of connecting line,then connect it to the terminal block and tighten screw. 2.
INSTALLATION MANUAL FOR WIRE CONTROLLER Upper cover of wire controller 1.Remove the upper cover of wire controller The PC board is installed on the back cover of wire controller. When remove the upper cover, pay attention not to damage PC board. HEALTH C F SET RECOVERY CHECK Back cover of wire controller 2.Install wire controller **Drill 2 wall holes according to the position of the 2 screw holes on the back *cover of wire controller, then hit wood in the wall holes.
CHECK AND TEST RUN Other instruction 1.Set of the air sending of the fan motor Before leaving factory, the rotation speed of fan motor has already been set at standard choice. When the indoor unit uses free air sending and not needing to connect with duct, the fan speed of indoor unit is set at standard choice. When the indoor unit needs to connect with duct, please according to the following figure shown to change the connection of the connector installed on the side of electric box.