SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL HSU-07HC03/R2 HSU-09HC03/R2 HSU-12HC03/R2 HSU-14HB03/R2 HSU-18HB03/R2 HSU-22HD03/R2 H2SM-14HB03/R2 H2SM-18HB03/R2 Please read this operation manual before using the air conditioner. No.
Cautions Disposal of the old air conditioner All these valuable materials may be taken to a waste collecting center and used again after adequate recycling. Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner Consult your local authorities for the name and address of the waste materials collecting in order to avoid the risk of child entrapment. centers and waste paper disposal services nearest to your house.
Cautions Specifications For the purpose of the safety,the air conditioner must be properly grounded in accordance with specifications. The refrigerating circuit is leak-proof. Remark per EMC Directive 89/336/EEC. To prevent flicker impression during the start of the compressor(Technical Process) and the adversely influence caused by the 2nd harmonies of compressor following installation conditions do apply: 1.The power connection for air conditioner has to be done at the main power distribution.
Parts and Functions Indoor Unit Test running switch(manual) Used only for test running in cooling when room temp. is below 16oC. Don't use it in normal operation. Inlet grille Emergency switch(manual) Used when remote controller is lost or defective. Unit will run temporarily. Remote signal receiver Air filter A beeping sound is generated when a signal from remote controller is received. Vertical flap Use remote controller to adjust up and down air flow. (Don't adjust it manually.
Parts and Functions Outdoor Unit For models: HSU-07HC03/R2 HSU-09HC03/R2 CONNECTING PIPING AND ELECTRICAL WIRING INLET DRAIN HOSE OUTLET The machine is adaptive in following situation 1. Applicable ambient temperature range: Cooling Indoor Outdoor Indoor Heating Outdoor Maximum:D.B/W.B Minimum:D.B/W.B 32oC/23oC 18oC/14oC Maximum:D.B/W.B Minimum:D.B Maximum:D.B Minimum:D.B Maximum:D.B/W.B Minimum:D.B/W.B 43oC/26oC 18oC 27oC 15oC 24oC/18oC -7oC/-8oC 2.
Parts and Functions For models: HSU-12HC03/R2 For models: HSU-22HD03/R2 HSU-14HB03/R2 For models: HSU-18HB03/R2 For models: H2SM-14HB03/R2 H2SM-18HB03/R2 5
Parts and Functions Buttons and display of the remote controller. 1.Mode display AUTO COOL DRY HEAT FAN LOW MED HI AUTO 2. SWING display 3. FAN SPEED display 4. HEALTH display 5. SLEEP display 6. LOCK display 7. TIMER ON display 8. AUXILIARY HEAT display 9. HEALTH 10. MODE Used to select AUTO,COOL,DRY,HEAT and FAN 11. CLOCK Used to set correct time 12. TIMER Used to select TIMER ON,TIMER OFF 13. RESET Used to reset the controller back to normal condition. 14.
Parts and Functions Buttons and display of the remote controller. If the unit which you purchased has not health function, remote controller should like the following figure: 1.Mode display AUTO COOL DRY HEAT FAN LOW MED HI AUTO 2. SWING display 3. FAN SPEED display 4. HEALTH display 5. SLEEP display 6. LOCK display 7. TIMER ON display 8. AUXILIARY HEAT display 9. SWING 10. MODE Used to select AUTO,COOL and FAN 11. CLOCK Used to set correct time 12. TIMER Used to select TIMER ON,TIMER OFF 13.
Operation Remote controller's operation When in use, put the signal transmission head directly to the receiver hole on the indoor unit. The distance between the signal transmission head and the receiver hole should be within 7 m without any obstacle as well. Don't throw the controller, prevent it from being damaged.
Operation Auto run, Fan operation Enjoy yourself by just a gentle press. (1) Unit start Press ON/OFF button, unit starts. Previous operation status appears on display. (Not Timer setting) Power indicator on indoor unit lights up. (2) Select operation mode Press MODE button. For each press, operation mode changes as follows: AUTO COOL DRY HEAT Unit will run in selected mode. Stop display at " " AUTO or " FAN "FAN. (3) FAN Press FAN button.
Operation COOL,HEAT and DRY operation Recommendations: Use COOL in summer. Use HEAT in winter Use DRY in spring, autumn and in damp climate. (1) Unit start Press ON/OFF button, unit starts. Previous operation status appears on display. (Not Timer setting) Power indicator on indoor unit lights up. (2) Select operation mode Press MODE button. For each press, operation mode changes as follows: AUTO COOL DRY HEAT FAN Unit will run in operation mode displayed on LCD. Stop display at your desired mode.
Operation (5) Air flow direction adjustment After operation mode is selected, vertical flap will open automatically according to the mode. Referring to the Fig. COOL HEAT About 60o o About 10 Left and right air flow adjustment Press SWING button, vertical flap will move within (manual) Up and down (Use remote controller) the range shown in the Fig. Press SWING button stop it at a fixed position.
Operation TIMER Operation Set Clock correctly before starting Timer operation You can let unit start or stop automatically at following times: Before you wake up in the morning, or get back from outside or after you fall asleep at night. TIMER ON/OFF (1)After unit start, select your desired operation mode. Operation mode will be displayed on LCD. Power indicator on indoor unit lights up. (2)TIMER mode selection Press TIMER button to change TIMER mode.
Operation TIMER ON-OFF TIMER ON-OFF (1)After unit start, select your desired operation mode. Operation mode will be displayed on LCD. Power indicator on indoor unit lights up. (2) Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: ON OFF ON OFF blank TIMER ON TIMER OFF TIMER ON-OFF Select TIMER ON-OFF. "ON" will flash. (3)Time setting for TIMER ON Press HOUR button. Every time the button is pressed, time increases 10 min.
Operation HEALTH Mode operation (1) Press the ON/OFF switch. (2) Press the "HEALTH" once," " is displayed, now the air conditioner is operating the health function. (3) Press the "HEALTH"again,then the health function stops.
Operation Emergency and Test Operation Emergency operation: Use this operation only when the remote controller is defective or lost. When the emergency operation switch is pressed,the" Pi "sound is heard once, which means the start of this operation. In this operation, it is possible to change the settings of temperature and air flow speed, it is Pi also impossible to do an operation by the timer. Follow the requirements below.
Operation Comfortable SLEEP Before going to bed at night, you can simply press the SLEEP button and unit will bring you a sound sleep in selected mode. In COOL mode One hour after SLEEP mode starts, temp. will o become 1 C higher than temp. setting. After o running for another 1 hour, temp. rises by 1 C further. Unit will run for 6 hours then stops automatically. Temp. is higher than temp. setting so that room temp. won't be too Iow for your sleep.(As shown in Fig.
Maintenance Different models have different appearance Cleaning of unit casing Cut off power supply before cleaning unit casing with soft cloth. In case of heavy stain, clean it with neutral detergent. squeeze water in the cloth, wipe off the detergent on unit casing completely. Cleaning of remote controller Cleaning of air filter Don't use water to wash unit casing, please use dry cloth. Don't use glass cleaner or cloth soaked with chemicals. Air Filter 1.Open inlet grille by pulling it upward. 3.
Maintenance Replacement of Purifying Filter 1 Open the Inlet Grille Open the inlet grille by pushing each end of the inlet grille upward. 2 Detach the standard air Filter Slide the knob slightly upward to release the filter,then withdraw it. 3 Detach the Air Purifying Filter Air Filter Replace old Air Purifying Filter with new one into the frame. 4 Attach the Air Purifying Filter Attaching each of the Air Purifying Filters to the indoor unit as white side face to front.
Maintenance Better use of air conditioner Proper room temperature. Cleaning of the air filter. Once every two weeks Proper temperature Effective use of the timer. Closing of doors and windows during operation Curtains or blinds for windows Avoid time-wasteful operation Never fail to observe the followings Do not sprinkle water over the unit. Do not block the inlet or outlet. Do not pull power plug. Do not use for other purposes. Such as food preservation plant cultivation or animal breeding.
Trouble shooting Before asking for service, check the following first. Phenomenon Cause or check points The system does not restart immediately. When unit is stopped, it won't restart immediately until 3 minutes have elapsed to protect the system. When the electric plug is pulled out and reinserted, the protection circuit will work for 3 minutes to protect the air conditioner. During unit operation or at stop, a swishing or gurgling noise may be heard.