FOR ALTERNATIVE PIPING METHODS TO CON-
NECT THE APPLIANCE TO THE GAS SUPPLY, A
TRAINED SERVICE MAN OR GAS APPLIANCE
IN-STALLER MUST MAKE THE GAS
SUPPLYCONNECTION. Leak testing of the
appliance shall be conducted by the Installer
according to the Instructions given.
Unless prohibited by
local codes or ordinances, a new
A.G.A. - Certified, flexible metal appliance connector
may be used to connect this appliance to its gas sup-
ply. The connector must have an internal diameter not
less than nominal 1/2” NPT pipe and be no more than
5 feet in length. A 1/2” NPT x 1/2” flare union adapter
is required at each end of the flexible connector.
If a flexible connector is used assure that both the
appliance pressure regulator and manual shut-off
valve are joined solidly to other permanent hard
piping (either gas supply or the appliance manifold)
so as to be physically stationary. See figure 12.
CAUTION
Do not attempt to attach the flexible connector directly
to an external pipe thread.
Connection requires flare union adapters.
For Massachusetts Installations:
1. Shut-off valve must be a "T" handle gas cock.
2.
Flexible gas connector must not be longer than
36 inch.
3. Not approved for installation in a bedroom or a
bathroom unless unit is direct vent.
MANIFOLD
ENTRANCE
GASKET
GASKET
FLARE
UNION
ADAPTOR
FLARE UNION
ADAPTOR
1/2" NPT
PIPE NIPPLE
ELBOW
1/2" NPT
PIPE NIPPLE
1/2" NPT PIPE
(STATIONARY
SUPPLY PIPE)
1/2" NPT PIPE
(STATIONARY
SUPPLY PIPE)
NO APPLIANCE
MOUNTED BELOW
THIS COOKTOP
WALL OVEN MOUNTED
IN CABINETRY BELOW
THIS COOKTOP
GAS
SHUT-OFF
VALVE
GAS
SHUT-OFF
VALVE
FLEXIBLE
APPLIANCE
CONNECTOR
5 FT. MAX
(1.52 m) MAX
()
FLEXIBLE
APPLIANCE
CONNECTOR
5 FT. MAX
(1.52 m) MAX
()
FLARE
UNION
ADAPTOR
FLARE
UNION
ADAPTOR
FLARE
UNION
ADAPTOR
APPLIANCE
PRESSURE REGULATOR,
SUPPLIED (OBSERVE
DIRECTIONALITY
OF GAS FLOW)
APPLIANCE
PRESSURE
REGULATOR,
SUPPLIED (OBSERVE
DIRECTIONALITY
OF GAS FLOW)