Solar Water Heater QBJ1-130A58E QBJ1-150A58E QBJ1-175A58E QBJ1-200A58E QBJ1-230A58E QBJ1-270A58E Please read this manual before usage Retain it for future reference Instruction for use
Content Technical data Features Appearance and parts Technical parameter 1 1 1 Precautions 2 Before use 3 Notice 3 Assembly Instruction The location 4 Exterior and installation dimension 4 Tank assembly 5 Frame assembly 5 Frame fastness 5 Glass tube assembly 6 Extraventricular plumbing instructions 7 Indoor plumbing instructions 7 Installation notice 8 Pipelines thermal insulation notice 9 The product with controller installation and using notice 9 Using Instruction The operati
Technical data Features 1. 2. 3. 4. Inner cylinder: SUS 304 stainless steel, food grade. Insulation: Polyurethane foam, thickness-45 mm, good heat preservation effect. Outer shell: Aluminium / zinc coated steel sheet. Frame: Steady structure, shapely and durable .
Precautions Precautions 1.When using the water heater with electric heating, ensure that electric heating and electric tracing belt are closed. 2. Avoiding irradiation without water after installation, it can't be used immediately, it should be sheltered. 3. When supplying water at the first time, it should be operated in the morning or evening or the condition of short of light; avoid supplying water in strong sunshine, in order to prevent vacuum tubes bombing. 4.
Before use Notice Please take time to read this manual and familiarize yourself with the function of this production. 1. Please check out the packing list. 2.If you fix electric auxiliary heating and controller, please select Haier equipped products. 3. To avoid the scald, please mix the hot and the cold water before use it. 4. In order to protect the tank ,please don't refit or wall up the air supply pipe and the overflow pipe.
Assembly Instruction The location: 1. Please install the solar water heater in the area that avoid the thunder. 2. Solar water heater angle range: east to south for 10 , west to south for 15 . 3. There shouldn't be any hindrance in front of the heater ,or the distance should over L, L=H/tg(66.5 a) H:height of the hindrance; a: latitude of the area Notice: The solar water heater shall be installed by professional.
Assembly Instruction Tank assembly 1. Unpacking the tank, rip off the protection film. Uninstall the nut and cushion. 2. Place tank onto tank bracket cradle, inserting protruding bolts into holes. fasten with nuts. Notice: 1. Rip off the protection film after the installation to avoid the destroy of the tank, and please don't use the sharp tool. 2. Leave nuts loose since some adjustment may be necessary after fitting tubes. 3.
Assembly Instruction Glass tube assembly 1. Keep tubes out of the irradiation while assembling the unit or a scald may be caused. 2. Place the rounded side of rubber seal downwards on the open end of tubes.(A) 3. Insert the tube into base support of locating hole with gentle pressure and twisting motion. 4. Holding the tube, fix base support into base bracket (B), insert tube into base support (C). 5. Slide the tube down 1 cm, Slide black rubber seal up the tubes until it sits flush with tank(D). 6.
Assembly Instruction Extraventricular plumbing instructions Over flow pipe Air supply pipe Sensor Electric heating pipe Air supply hole(1/2 ) forbidden to stem Over flow hole ( conect to the room Inlet/outlet hole (1/2 ), conect to the room Electric heating flange Sensor hole 3/4 a A QBJ1-130A58E QBJ1-150A58E QBJ1-175A58E QBJ1-200A58E b QBJ1-230A58E A b a Remarks: The permitted error limit of above parameters is Indoor plumbing instructions Solar water heater Water level sensor Electric hea
Assembly Instruction Installation notice 1. Any alteration to the structure of the solar water heater may cause the trouble while using it. 2. There are 5 connection methods of the water pipe into the room, they are smoke way, vent-pipe hole on the wall appropriative solar well prepared cannula and the first three kinds are common. Before the installation, our professional will consult the room's situation and choose the suitable location to bring you convenience.
Assembly Instruction Pipelines thermal insulation notice 1.Outdoor pipelines should be thermal insulated according to local climate, bad thermal insulation may lead to heat loss. 2.The outlet used by electric tracing belt must ground reliably. The rated current of outlet is less than 10A, ensure is connected to plug reliably. 3.Fixing electric tracing belt on cold and hot water pipes, in order to touch well, it should be fixed with insulating tape per 500 mm. 4.
Assembly Instruction Using Instruction 7.If the controller you choose has automatic water supply function, electromagnetic valve must be fixed in room horizontally; the direction of arrowhead labled on valve is the direction of water running out. Suggest fixing manual water supply side line, ensure that users can use water heater normally when the electromagnetic valve is damaged. 8.
Using Instruction Troubles treatment Phenomenon Possible reason Treatment Supply water according to the manual The tank is empty No water supply The pipeline or the connection Maintain the pipeline or clean is impeded the connection The controller can't reach the programmed level or there is no water The evacuated tubes have damaged Replacing the tubes The water supply is paused or low Waiting for the supplying again water pressure The pipeline or the connection is Damaged Maintain the pipeline and
Made in China Rev.