Overflow
The overflow indicator pipe from the integral cistern needs to be run to a suitable position. A 0.75” nominal push
in socket is fitted to the cistern for customer connection.
• Ensure that discharge from the overflow is visible.
Don’t connect the overflow directly into the soil drain. A tundish device may be used
Electrical information
Quattro is supplied for use on single phase power supplies; refer to the rating label details on the top of the
electrical connection cover of the machine.
• All electrical installations comply with current National Electrical Code regulations.
• Appropriate National Electrical Code approved cables have been used.
• The appliance is connected to a protective ground connection via the ground terminal and identified
by the ground label.
• A dedicated, acceptable motor control switch with a marked OFF position shall be provided at
the time of installation to disconnect the disposer from all ungrounded supply conductors.
• Isolator switch (customer supply) to be mounted adjacent and in sight of the appliance.
• Electrical connection is made into the 120V Control Box.
Please Note: Mains cable is NOT supplied with machine
L
N
• Mains cable to be routed through cable
gland at rear of machine for strain relief.
• Mains cable to be routed through cable
clamp located on base of machine.