Unpacking the machine
1. Remove the carton and any packing materials
2. Remove the front panel screw, hold both sides of the front panel at the bottom and pull to release it and
access the interior
3. Remove the electrical control box to access the central fixing down bolt
4. Remove the central fixing down bolt
Floor Bracket Fastener Details:
Type: hexagonal Head (13 A/F)
Size: M8 x 20mm
5. Replace the control box and remove the machine from the pallet
6. Remove the bolts that secure the floor locating bracket to the pallet. The floor locating bracket will be used
to fix the machine to the floor and is positioned by using the template (supplied)
7. The machine is now ready for installation.