Identification of fault codes
Problem
Possible causes / resolution
Latch not engaged, display flashes
F3
Contactor circuit fault:
• Check operation of rear positive break switch.
• Main contactor fault.
• Check contactor connections, replace contactor if necessary.
F4
Overload trip:
Motor has tripped out on overload, probably jammed therefore switch off at isolator
and remove the obstruction from the hopper.
F5
Drain Block Stage 1:
Pressure in hopper has built up to trigger the pressure switch but the machine
recovered and continued.
F6
Drain Block Stage 2
Pressure in hopper:
• Blockage in pulveriser exit or drain. Investigate the cause and clear the blockage.
• Incorrect installation, pipe size, or position of waste pipework. 50mm minimum.
• Non return/in line valves not operating correctly. Clean or replace as required.
• Never use a reactive chemical drain block clearer within the machine as it will
damage the seals.
F7
Cistern fails to replenish with water after 150 seconds:
• Lack of water in cistern:
• Check that the mains inlet valve is open.
• Check that there is sufficient water pressure.
• Check and clean the inlet solenoid filter.
• Check solenoid valve is operating. Replace if required.
F8
(Logged Only)
Water level fails to drop after 20 seconds:
• Pump not operating or level sensor problem:
• Check the pump and replace if faulty.
• Check the cistern level switch and replace if faulty.
F9
(Logged Only)
Motor speed sensor failure:
• Caution only, machine reverts to a safe state to ensure that motor has stopped
before the interlock is released.
F10
Hinge Actuator Fault, Lid fails to open or close within 4s.
• Check that nothing is obstructing the lid.
• Check lid open and closed micro switches for continuity.