Controls and Indicators
27
CAFSPro User Operation Manual
p/n: 029-0020-75-0
The WET and DRY ARROW buttons change the type of CAF discharge
produced. The LED bar graph shows the finished CAF consistency,
dependent on the number of LEDs that light.
CAUTION !
DO NOT EXCEED 195
°
F (91
°
C) DURING AIR COMPRESSOR SYSTEM
OPERATION.
Audible Alarm
(See Figure 3-8: “Audible Alarm.”)
The audible alarm is mounted on the oper-
ator panel. The alarm provides the follow-
ing warnings:
When the air compressor oil temper-
ature exceeds 205
°
F (96°C)
When the foam concentrate is run-
ning low
The compressed air foam operation
will end if the foam concentrate tank
is not filled
The compressor drive clutch is disen-
gaged
Along with other operational signals and warnings during system
operations.
Figure 3-8: Audible Alarm