Installation Guide

EM200IG-1900805
2. In the Halio Component Cabinet, center the Energy
Manager over the set of 4 pre-drilled holes provided.
If this is the first or only Energy Manager in this
cabinet, use the pre-drilled holes located just above
the terminal block (as pictured below).
If this is the second or third Energy Manager in this
cabinet, use an addition set of pre-drilled holes
located higher in the cabinet.
3. Use the 4 screws provided with Energy Manager to secure
Energy Manager in the cabinet.
4. Wire the 8-pair unterminated wires of Energy Manager
Power Output Cable to the appropriate blue (+) and gray
(-) power input terminals on the left side of the
Component Cabinet terminal block.
5. Plug the other end of the Energy Manager Power Output
Cable (with the pre-wired 8-pair connector plug) into the
power output port on the left side of Energy Manager.
6. Locate the 4 unterminated wires of the System Power
Supply Power Output Cable (routed inside the Component
Cabinet), and then wire them to the 4 unterminated wires
of Energy Manager Power Input Cable using the 4 lever-
nuts provided. Be sure to connect them by colors: red to
red, white to white, green to green, and black to black.