Instructions / Assembly

4
INSTALLATION INSTRUCTIONS
This appliance shall only be installed by an authorized person. This appliance shall be installed in
accordance with the manufactures installation instructions, IMPORTANT: this appliance must be installed in
accordance with the norms in force of the country concerned.
The installation of this appliance must conform to local codes and ordinances. In the absence of local codes.
Installations must conforms to American National Standards, National Fuel Gas Code ANSI Z223.1-54
If local codes permit, a exible metal appliance connection with the new AGA or CGA certi ed design,
max. 5 feet (1,5m) long, ½” I.D. recommended for connecting this cooktop to the gas supply line. Do not
bend or damage the exible connector when moving the cooktop. The pressure regulator has ½” female
pipe thread. You will need to determine the tting required, depending on the size of your gas supply line,
the exible metal connector and the shuto valve.
The appliance , when installed, must be electrically grounded in accordance with local codes or, in absence
of local codes, with the National Electrical Code, ANSI/NFPA 70.
The appliance and its individual shut o valve must be disconnected from the gas supply piping system
any pressure testing of that system at test pressure in excess of ½psi (3,5kPa).
The appliance must be isolated from the gas supply piping system by closing its individual manual shuto
valve during any pressure testing of the gas supply piping system at test pressure equal to or less than
½psi (3,5kPa).
For use with a pressure regulator. The regulator supplied must be used with this appliance; it shall be
properly installed in order to be accessible when appliance is installed in de nitive position.
The gas appliance pressure regulator must be set for the gas with which the appliance is used.
This appliance can be used with Natural gas and LP Gas. It is shipped from the factory adjusted for use
with Natural gas: CONVERSION FIXED ORIFICES ARE LOCATED IN THE LITERATURE PACK SUPPLIED
WITH THE UNIT.
Injectors kit for the change of type of gas are contained inside the package jointly with the hob installation
kit and Instruction booklet. The maximum inlet gas supply pressure incoming to the gas appliance pressure
regulator is 20” water column (5kPa). The minimum gas supply pressure for checking the regulator setting
shall be at least 1”w.c.(249Pa) above the inlet speci ed manifold pressure to the appliance (this operating
pressure is 5”w.c. for Natural Gas and 10”w.c. for LP Gas.All opening and holes in the wall and oor, back
and under the appliance shall be sealed before installation of the appliance.
ATTENTION: A manual valve shall be installed in an accessible location in the gas line external to the appliance for the
purpose of turning on or shutting off gas to the appliance.
WARNING: Do not use aerosol sprays in the vicinity of this appliance while it is in operation.
The appliances should not be installed with a ventilation system that blows air downward toward the range.