PERFORMANCE CHECKLIST
All burners are tested before leaving the factory. There are no adjustments for the burners
if connected according to the information on the rating plate. Check each burner for proper
operations. Flames should be blue in all settings. If service is required, contact your dealer for
the name of their authorized service agency. Gas conversions and initial installation are not
responsibility of the manufacturer.
The installer should carry out the following performance checks. Refer to instructions below.
1. Check surface burner ignition.
2. Check air shutter adjustment (only for oven and broiler burner) sharp blue ame, no yellow tipping, shooting or
ame lifting.
3. Check low ame adjustment
4. Check broiler and oven ignition - all burners ports.
5. Check for gas leaks (odors) at all gas connections.
6. Check oven bake and convection bake function.
REQUIREMENTS
Room ventilation – Location and venting.
ATTENTION: A exhaust fan may be used with the appliance; in each case it shall be installed in conformity with the
national standards in force.
ATTENTION: Exhaust hood operation may affect other vented appliances; in each case it shall be installed in conformity
with the national standards in force.
CONVERSION TO DIFFERENT TYPES OF GAS
Any conversion required must be performed by your dealer or a qualified licensed plumber or gas service company.
Please provide the service person with this manual before work is started on the range.(Gas conversions are the
responsibility of the dealer or end user.)
WARNING
This conversion kit shall be installed by a qualified service agency in accordance with the
manufacturer’s instructions and all applicable codes and requirements of the authorityhaving
jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or
production of carbon monoxide may result causing property damage, personal injury or loss of life.
The qualified service agency is responsible for the proper installation of this kit. The installation
is not proper and complete until the operation of the converted appliance is checked as specified
in the manufacturer’s instructions supplied with the kit.
CAUTION
Before proceeding with the conversion, shut off the gas supply to the appliance prior to disconnecting
the electrical power.
The appliance is supplied for use with a certain type of gas; if this has to be varied, you must change the burner
injectors, adjust the air flow rate and the minimum gas flow.
Before carrying out these operations you must disconnect the electric power supply of the cooker to avoid accidental
contacts.
Before carrying out any maintenance work, disconnect the appliance from the gas and electric supply.