Installation Guide

15
3-Wier Cable from Power Supply to 4-Wire Cable from
Cooktop
4-Wier Cable from Power Supply to 3-Wire Cable from
Cooktop
IMPORTANT: Use the 3-wire cable from power supply where
local codes permit connecting the frame-ground conductor to
the neutral (white) junction box wire:
A.3-Wire cable from power
B. Red wires
C. White and green or bare
D. 4-wire cable from cooktop
E. Junction box
F. White wire (from power
G. UL listed wire connector
H. Black wires
I. UL listed or CSA approved
1. Disconnect power.
2. Remove junction box cover if present.
3. Connect the flexible, cable conduit from the cooktop to the
junction box using UL listed or CSA approved conduit
4. Tighten screws on conduit connector, if present.
5. Connect the two black wires together using the UL listed wire
6. Connect the two red wires together using the UL listed wire
7. Connect the green or bare and white cooktop cable wires to
the white (neutral) wire in the junction box using the UL listed
8. Install junction box cover.
9. Reconnect power.
wire connectors.
supply)
ground wires (from cooktop)
supply
conduit connector
connector.
connectors.
connectors.
IMPORTANT: Use the 4-wire cable from power supply where
local codes do not permit connecting the frame-ground
the neutral (white) junction box wire:
A.4-Wire cable from power
B. Red wires
C. Green or bare ground wire
D. 3-wire cable from cooktop
E. Junction box
F. White wire (from power supply)
G. UL listed wire connector
H. Black wires
I. UL listed or CSA approved
conductor to
(from cooktop)
conduit connector
1. Disconnect power.
2. Remove junction box cover if present.
3. Connect the flexible cable conduit from the cooktop to the
junction box using a UL listed or CSA approved conduit
4. Tighten screws on conduit connector, if present.
5. Connect the two black wires together using the UL listed wire
6. Connect the two red wires together using the UL listed wire
7. Connect the green or bare ground wire from the cooktop
cable to the green or bare ground wire (in the junction box )
8. Put UL listed wire connector on the end of the white wire.
NOTE: Do not connect the bare ground wire to the neutral
9. Install junction box cover.
10. Reconnect power.
(white)wire in the junction box.
using the UL listed wire connectors.
connectors.
connectors.
connector.
supply