Use and Care Manual
19
Gas Cooktop Conversion and Adjustment Guide
The cooktop is set for use with Natural Gas (NG). The factory setting is indicated
on the serial plate. When set for Liquefied Petroleum (LPG) operation, the pressure
regulator will regulate the pressure to 11 inches water column. When set for NG Gas
operation, the pressure regulator will regulate the gas to 4” inches water column
pressure.
NG to LPG Conversion
Convertible Pressure Regulator
The cooktops are shipped to operate on NG. LPG orifices are shipped with the unit
in a separate envelope with the manual. Save the NG orifices removed from the
appliance for future use, make sure you note which orifices are for which burner if
you plan on converting back to NG.
The inlet pressure of the gas supply shall be in accordance with the nominal inlet
pressure of the regulator used on the cooktop or 1/2 psig maximum. The cooktop
should be tested by pressurizing the regulator with an inlet pressure at least 1 inch
water column above the manufacturer's specified manifold pressure shown on the
serial plate.
1. Shut off gas leading to appliance.
2. Unplug any electrical connections if you are using the 110V option, usually
located under the cooktop.
3. Locate convertible regulator under the cooktop, remove cap and pop out the
pin that’s attached.
4. Below you will see the pin positon for use with NG.
5. Pull out pin and flip it to the LPG position – see below.