12. Once all the orifices are installed, replace all burners and burner caps, then fire up
the burners to check the minimum flame height.
13. Minimum flame height should be approx. ¼” tall. You will want a small
minimum flame for simmering (especially on the small burners). There is a small
adjustment screw located on the valve itself, the lid must be removed in order to
make the adjustment. The black cap on the valve has a hole in it located on the
lower right side which allows you to make the adjustment without removing the
black cap. Using a 3/32'' X 3” screwdriver or similar you can make the
adjustment through this hole. You can also pop off the black square cap as
shown below and make the adjustment. Turn the adjustment screw counter
clockwise for a smaller flame and clockwise for a larger flame.
14. Replace the lid, burners, burner caps and grates and recheck the flame.
LPG to NG Conversion
If you are looking to convert the appliance back to NG again, please locate the NG
orifices you stored with your manual from the previous conversion.
Convertible Pressure Regulator
The inlet pressure of the gas supply shall be in accordance with the nominal inlet
pressure of the regulator used on the cooktop or 1/2 psig maximum. The cooktop
should be tested by pressurizing the regulator with an inlet pressure at least 1 inch
water column above the manufacturer's specified manifold pressure shown on the
serial plate.
Adjustment location