PD610/PD615/PD620/PD630
PDM6A
64V
PHOTOMETRY - 1500 lumen / 80 CRI
PHOTOMETRY - 1500 lumen / 90 CRI
PD615ED010- PDM6A935-64VG
Spacing Criteria = 0.97
Lumens per Watt = 72 Lm/W
Test No. P167118
Test Model: PD615ED010- PDM6A935-64VG
Luminance
(Average Candela/M
2
)
Degree Avg.
Luminance
45 24499
55 13811
65 4112
75 0
85 0
Zonal Lumen Summary
Zone Lumens % Fixture
0-30 627 47.1
0-40 925 69.4
0-60 1297 97.3
0-90 1332 100
Candela Distribution
Degrees
Vertical
Candela
0* 945
5 936
10 898
20 758
30 567
40 393
50 227
60 78
70 5
80 0
90 0
*CBCP
Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot.
Footcandle values are initial, apply appropriate light loss factors where necessary.
Cone of Light Footcandles
Distance to
Illuminated
Plane
Initial Nadir
Footcandles
Beam (ft.)
L
Length
W
Width
5.5 31.2 5.2 5.2
7 19.3 6.6 6.6
8 14.8 7.6 7.6
9 11.7 8.6 8.6
10 9.5 9.6 9.6
12 6.6 11.6 11.6
Candlepower Distribution
Eyeball at 0-degrees
15º
350
700
1050
30º
45º
60º
75º
90º
PRM
TMM
NMRM
M˚ NR˚ PM˚
QR˚
SM˚
TR˚
VM˚
Halo Commercial
PD615ED010- PDM6A835-64VG
Spacing Criteria = 0.97
Lumens per Watt = 92.4 Lm/W
Test No. P167114
Test Model: PD615ED010- PDM6A835-64VG
Luminance
(Average Candela/M
2
)
Degree Avg.
Luminance
45 31422
55 17710
65 5279
75 0
85 0
Zonal Lumen Summary
Zone Lumens % Fixture
0-30 805 47.1
0-40 1186 69.4
0-60 1664 97.3
0-90 1709 100
Candela Distribution
Degrees
Vertical
Candela
0* 1212
5 1200
10 1152
20 972
30 727
40 505
50 292
60 100
70 6
80 0
90 0
*CBCP
Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot.
Footcandle values are initial, apply appropriate light loss factors where necessary.
Cone of Light Footcandles
Distance to
Illuminated
Plane
Initial Nadir
Footcandles
Beam (ft.)
L
Length
W
Width
5.5 40.1 5.2 5.2
7 24.7 6.6 6.6
8 18.9 7.6 7.6
9 15 8.6 8.6
10 12.1 9.6 9.6
12 8.4 11.6 11.6
Candlepower Distribution
Eyeball at 0-degrees
15º
450
900
1350
30º
45º
60º
75º
90º
QRM
VMM
NPRM
M˚ NR˚ PM˚
QR˚
SM˚
TR˚
VM˚
Scaling factor for the Battery back up:
- 1000 Lumen = 0.55
- 1500 Lumen = 0.40
- 2000 Lumen = 0.33
- 3000 Lumen = 0.22
Scaling factor for the Battery back up:
- 1000 Lumen = 0.55
- 1500 Lumen = 0.40
- 2000 Lumen = 0.33
- 3000 Lumen = 0.22