Specification

PHOTOMETRY - 1500 lumen / 90 CRI
PD610/PD615/PD620/PD630
PDM6A
61V
Halo Commercial
PHOTOMETRY - 1500 lumen / 80 CRI
PD615ED010- PDM6A935-61VC
Spacing Criteria = 0.76
Lumens per Watt = 68.1 Lm/W
Test No. P166942
Test Model: PD615ED010- PDM6A935-61VC
Luminance
(Average Candela/M
2
)
Degree Avg.
Luminance
45 5132
55 535
65 246
75 191
85 0
Zonal Lumen Summary
Zone Lumens % Fixture
0-30 948 75.3
0-40 1192 94.6
0-60 1257 99.8
0-90 1260 100
Candela Distribution
Degrees
Vertical
Candela
0* 1783
5 1728
10 1573
20 1132
30 652
40 178
50 20
60 3
70 1
80 0
90 0
*CBCP
Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot.
Footcandle values are initial, apply appropriate light loss factors where necessary.
Cone of Light Footcandles
Distance to
Illuminated
Plane
Initial Nadir
Footcandles
Beam (ft.)
L
Length
W
Width
5.5 58.9 4 4
7 36.4 5.2 5.2
8 27.9 6 6
9 22 6.8 6.8
10 17.8 7.6 7.6
12 12.4 9 9
Candlepower Distribution
Eyeball at 0-degrees
15º
600
1200
1800
30º
45º
60º
75º
90º
SMM
NOMM
NUMM
M˚ NR˚ PM˚
QR˚
SM˚
TR˚
VM˚
PD615ED010- PDM6A835-61VC
Spacing Criteria = 0.76
Lumens per Watt = 87.3 Lm/W
Test No. P166938
Test Model: PD615ED010- PDM6A835-61VC
Luminance
(Average Candela/M
2
)
Degree Avg.
Luminance
45 6582
55 688
65 311
75 254
85 0
Zonal Lumen Summary
Zone Lumens % Fixture
0-30 1217 75.3
0-40 1529 94.6
0-60 1613 99.8
0-90 1616 100
Candela Distribution
Degrees
Vertical
Candela
0* 2287
5 2216
10 2018
20 1452
30 836
40 228
50 25
60 4
70 1
80 0
90 0
*CBCP
Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot.
Footcandle values are initial, apply appropriate light loss factors where necessary.
Cone of Light Footcandles
Distance to
Illuminated
Plane
Initial Nadir
Footcandles
Beam (ft.)
L
Length
W
Width
5.5 75.6 4 4
7 46.7 5.2 5.2
8 35.7 6 6
9 28.2 6.8 6.8
10 22.9 7.6 7.6
12 15.9 9 9
Candlepower Distribution
Eyeball at 0-degrees
15º
800
1600
2400
30º
45º
60º
75º
90º
UMM
NSMM
OQMM
M˚ NR˚ PM˚
QR˚
SM˚
TR˚
VM˚
Scaling factor for the Battery back up:
- 1000 Lumen = 0.55
- 1500 Lumen = 0.40
- 2000 Lumen = 0.33
- 3000 Lumen = 0.22
Scaling factor for the Battery back up:
- 1000 Lumen = 0.55
- 1500 Lumen = 0.40
- 2000 Lumen = 0.33
- 3000 Lumen = 0.22