Specification

PD610/PD615/PD620/PD630
PDM6A
61V
Halo Commercial
PHOTOMETRY - 2000 lumen / 80 CRI
PD620ED010- PDM6A935-61VC
Spacing Criteria = 0.76
Lumens per Watt = 69.7 Lm/W
Test No. P137025
Test Model: PD620ED010- PDM6A935-61VC
Luminance
(Average Candela/M
2
)
Degree Avg.
Luminance
45 6241
55 650
65 298
75 233
85 0
Zonal Lumen Summary
Zone Lumens % Fixture
0-30 1154 75.3
0-40 1450 94.6
0-60 1530 99.8
0-90 1532 100
Candela Distribution
Degrees
Vertical
Candela
0* 2168
5 2102
10 1913
20 1377
30 793
40 217
50 24
60 3
70 1
80 0
90 0
*CBCP
Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot.
Footcandle values are initial, apply appropriate light loss factors where necessary.
Cone of Light Footcandles
Distance to
Illuminated
Plane
Initial Nadir
Footcandles
Beam (ft.)
L
Length
W
Width
5.5 71.7 4 4
7 44.3 5.2 5.2
8 33.9 6 6
9 26.8 6.8 6.8
10 21.7 7.6 7.6
12 15.1 9 9
Candlepower Distribution
Eyeball at 0-degrees
15º
750
1500
2250
30º
45º
60º
75º
90º
TRM
NRMM
OORM
M˚ NR˚ PM˚
QR˚
SM˚
TR˚
VM˚
PD620ED010- PDM6A835-61VC
Spacing Criteria = 0.76
Lumens per Watt = 89.4 Lm/W
Test No. P137021
Test Model: PD620ED010- PDM6A835-61VC
Luminance
(Average Candela/M
2
)
Degree Avg.
Luminance
45 8009
55 832
65 376
75 318
85 0
Zonal Lumen Summary
Zone Lumens % Fixture
0-30 1480 75.3
0-40 1860 94.6
0-60 1962 99.8
0-90 1966 100
Candela Distribution
Degrees
Vertical
Candela
0* 2782
5 2696
10 2454
20 1766
30 1017
40 278
50 31
60 4
70 2
80 0
90 0
*CBCP
Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot.
Footcandle values are initial, apply appropriate light loss factors where necessary.
Cone of Light Footcandles
Distance to
Illuminated
Plane
Initial Nadir
Footcandles
Beam (ft.)
L
Length
W
Width
5.5 92 4 4
7 56.8 5.2 5.2
8 43.5 6 6
9 34.3 6.8 6.8
10 27.8 7.6 7.6
12 19.3 9 9
Candlepower Distribution
Eyeball at 0-degrees
15º
950
1900
2850
30º
45º
60º
75º
90º
VRM
NVMM
OURM
M˚ NR˚ PM˚
QR˚
SM˚
TR˚
VM˚
PHOTOMETRY - 2000 lumen / 90 CRI
Scaling factor for the Battery back up:
- 1000 Lumen = 0.55
- 1500 Lumen = 0.40
- 2000 Lumen = 0.33
- 3000 Lumen = 0.22
Scaling factor for the Battery back up:
- 1000 Lumen = 0.55
- 1500 Lumen = 0.40
- 2000 Lumen = 0.33
- 3000 Lumen = 0.22