Dimensions Guide

PD610/PD615/PD620/PD630
PDM6A
61WW
Halo Commercial
PHOTOMETRY - 3000 lumen / 80 CRI
PD630ED010- PDM6A835-61WWC
Spacing Criteria = 0.8
Lumens per Watt = 78 Lm/W
Test No. P137821
Test Model: PD630ED010- PDM6A835-61WWC
Luminance
(Average Candela/M
2
)
Degree Avg.
Luminance
45 48548
55 32209
65 28771
75 18872
85 6856
Zonal Lumen Summary
Zone Lumens % Fixture
0-30 1750 62.9
0-40 2302 82.7
0-60 2661 95.6
0-90 2783 100
Candela Distribution
Degrees
Vertical
Candela
0* 3042
5 2620
10 2190
20 1637
30 1192
40 807
50 439
60 278
70 159
80 39
90 0
*CBCP
Single Unit Footcandles
2.5' from wall
(distance from fixture along wall)
1 23.3 17.1 8 2.8 0.9 0.3 0.1
2 31 23.8 13.1 6 2.3 0.8 0.3
3 34.2 27.6 14.8 6.2 2.7 1.1 0.5
4 26.7 23.5 15.2 7.4 3 1.2 0.5
5 19.1 17.5 13.4 7.7 3.7 1.5 0.6
6 13.8 13 10.7 7.4 4 1.9 0.8
7 10.1 9.7 8.4 6.4 4.1 2.2 1.1
8 7.5 7.3 6.6 5.4 3.8 2.4 1.3
9 5.7 5.6 5.2 4.4 3.4 2.4 1.4
10 4.4 4.4 4.1 3.6 2.9 2.2 1.5
Multiple Unit Footcandles
2.5' from wall
(spacing between fixtures)
1 26.2 24.4 26.2
2 37 36.2 37
3 40.4 42.5 40.4
4 34.1 39.4 34.1
5 26.9 31.4 26.9
6 21.2 24.1 21.2
7 16.5 18.3 16.5
8 12.9 14 12.9
9 10.1 10.9 10.1
10 8.1 8.6 8.1
3
Multiple Unit Footcandles
2.5' from wall
(spacing between fixtures)
1 24.2 16.1 24.2
2 33.3 26.2 33.3
3 36.9 29.5 36.9
4 29.7 30.4 29.7
5 22.8 26.8 22.8
6 17.9 21.3 17.9
7 14.2 16.8 14.2
8 11.4 13.1 11.4
9 9.1 10.3 9.1
10 7.4 8.2 7.4
4
Candlepower Distribution
Eyeball at 0-degrees
15º
1100
2200
3300
30º
45º
60º
75º
90º
NNMM
OOMM
PPMM
M˚ NR˚ PM˚
QR˚
SM˚
TR˚
VM˚
LEGEND:
0-deg:
90-deg:
180-deg:
Scaling factor for the Battery back up:
- 1000 Lumen = 0.55
- 1500 Lumen = 0.40
- 2000 Lumen = 0.33
- 3000 Lumen = 0.22