Dimensions Guide

PD610/PD615/PD620/PD630
PDM6A
61WW
Halo Commercial
PHOTOMETRY - 1000 lumen / 90 CRI
PD610ED010- PDM6A935-61WWC
Spacing Criteria = 0.8
Lumens per Watt = 71.8 Lm/W
Test No. P137809
Test Model: PD610ED010- PDM6A935-61WWC
Luminance
(Average Candela/M
2
)
Degree Avg.
Luminance
45 15164
55 10064
65 8989
75 5888
85 2139
Zonal Lumen Summary
Zone Lumens % Fixture
0-30 547 62.9
0-40 719 82.7
0-60 831 95.6
0-90 869 100
Candela Distribution
Degrees
Vertical
Candela
0* 950
5 818
10 684
20 511
30 372
40 252
50 137
60 87
70 50
80 12
90 0
*CBCP
Single Unit Footcandles
2.5' from wall
(distance from fixture along wall)
1 7.3 5.3 2.5 0.9 0.3 0.1 0
2 9.7 7.4 4.1 1.9 0.7 0.3 0.1
3 10.7 8.6 4.6 1.9 0.8 0.3 0.1
4 8.3 7.3 4.7 2.3 0.9 0.4 0.2
5 6 5.5 4.2 2.4 1.1 0.5 0.2
6 4.3 4.1 3.3 2.3 1.3 0.6 0.3
7 3.1 3 2.6 2 1.3 0.7 0.3
8 2.3 2.3 2.1 1.7 1.2 0.7 0.4
9 1.8 1.7 1.6 1.4 1.1 0.7 0.4
10 1.4 1.4 1.3 1.1 0.9 0.7 0.5
Multiple Unit Footcandles
2.5' from wall
(spacing between fixtures)
1 8.2 7.6 8.2
2 11.6 11.3 11.6
3 12.6 13.3 12.6
4 10.7 12.3 10.7
5 8.4 9.8 8.4
6 6.6 7.5 6.6
7 5.1 5.7 5.1
8 4 4.4 4
9 3.2 3.4 3.2
10 2.5 2.7 2.5
3
Multiple Unit Footcandles
2.5' from wall
(spacing between fixtures)
1 7.6 5 7.6
2 10.4 8.2 10.4
3 11.5 9.2 11.5
4 9.3 9.5 9.3
5 7.1 8.4 7.1
6 5.6 6.7 5.6
7 4.4 5.3 4.4
8 3.5 4.1 3.5
9 2.8 3.2 2.8
10 2.3 2.6 2.3
4
Candlepower Distribution
Eyeball at 0-degrees
15º
350
700
1050
30º
45º
60º
75º
90º
PRM
TMM
NMRM
M˚ NR˚ PM˚
QR˚
SM˚
TR˚
VM˚
LEGEND:
0-deg:
90-deg:
180-deg:
Scaling factor for the Battery back up:
- 1000 Lumen = 0.55