Specification
HALO
®
Catalog #
Type
Project
Comments
Date
Prepared by
E4RTATSB
4” Non-Insulated Ceilng
AIR-TITE Remodel Housing
with Adjustable Socket
Bracket
4” Trims
Dimensions
Specification Features
Description
The E4RTATSB is a remodel Non-IC Air-Tite
TM
housing optimized and
listed for EISA compliant tungsten-halogen lamps, CFL and LED lamps
as well as incandescent. Housing features an adjustable socket bracket,
and is suitable for residential or commercial applications. Installation
in non-insulated ceilings with Air-Tite code compliant construction. If
insulation is present it must be kept 3” from all sides of the housing.
May be retrofit with compatible Halo LED lighting systems.
Housing
•
Die-formed CRS
•
For installation from below the
finished ceiling
•
Air-Tite gasket pre-installed on
remodel flange
Remodel Clips
•
Four remodel clips secure housing
and accommodates 1/2” and 5/8”
ceiling materials.
Junction Box
•
Seven conduit knockouts are uniform
1/2” size with true pry-out slots
•
Four pry-outs with integral strain
relief simplify “NM” non-metallic
sheathed cable installation
•
Three quick connect wire connectors
included
Includes:
Quick Connect™
•
(3) Push wire nuts included, for
speed & reliability
•
Clear caps for wire connection
visibility
Air-Tite™ code compliant
•
ASTM E283 compliant
Socket
•
Adjustable position porcelain socket
with nickel plated brass screw
shell provides flexibility in lamp
positioning.
Thermal Protector
•
Self resetting thermal protector
deactivates fixture if overheating
occurs due to improper lamping or
misapplied insulation.
Trims
•
Halo Fit-All concept offers
multiple trim options in a variety
of design styles, and functional
beam distributions to control
beam angle and lumen delivery in
accommodating various lamp types
Compliance
•
cULus Listed 1598 Luminaire
•
cULus Listed for Damp Location
•
cULus Listed for Wet Location, with
select trims
•
RoHS compliant
•
Air-Tite code compliant. Certified
under ASTM E283; not exceeding
2.0 cfm (0.944 L/s) air leakage rate
tested at a 1.57 psf (75 Pa) pressure
differential
FOR USE IN EXISTING
CEILINGS
FOR USE IN
NON-INSULATED CEILINGS
OR
INSULATED CEILINGS BUT
INSULATION MUST BE
KEPT 3” FROM ALL SIDES
OF FIXTURE
TD518104EN
2/29/2016
Special Features
Quick Connect™ push wire nuts
Air-Tite™ code compliant
4-1/4"
[108mm]
5"
[127mm]
11-1/2"
[292mm]
4-5/8"
[116mm]
Ceiling opening to match
template supplied
4-1/4"
[108mm]
5"
[127mm]
11-1/2"
[292mm]
4-5/8"
[116mm]
Ceiling opening to match
template supplied