E4RTATSB
4” Non-Insulated Ceilng
AIR-TITE Remodel Housing
with Adjustable Socket
Bracket
4” Trims
Dimensions
Specification Features
Description
The E4RTATSB is a remodel Non-IC Air-Tite
TM
housing optimized and
listed for EISA compliant tungsten-halogen lamps, CFL and LED lamps
as well as incandescent. Housing features an adjustable socket bracket,
and is suitable for residential or commercial applications. Installation
in non-insulated ceilings with Air-Tite code compliant construction. If
insulation is present it must be kept 3” from all sides of the housing.
May be retrofit with compatible Halo LED lighting systems.
Housing
Die-formed CRS
For installation from below the
finished ceiling
Air-Tite gasket pre-installed on
remodel flange
Remodel Clips
Four remodel clips secure housing
and accommodates 1/2” and 5/8”
ceiling materials.
Junction Box
Seven conduit knockouts are uniform
1/2” size with true pry-out slots
Four pry-outs with integral strain
relief simplify “NM” non-metallic
sheathed cable installation
Three quick connect wire connectors
included
Includes:
Quick Connect™
(3) Push wire nuts included, for
speed & reliability
Clear caps for wire connection
visibility
Air-Tite™ code compliant
ASTM E283 compliant
Socket
Adjustable position porcelain socket
with nickel plated brass screw
shell provides flexibility in lamp
positioning.
Thermal Protector
Self resetting thermal protector
deactivates fixture if overheating
occurs due to improper lamping or
misapplied insulation.
Trims
Halo Fit-All concept offers
multiple trim options in a variety
of design styles, and functional
beam distributions to control
beam angle and lumen delivery in
accommodating various lamp types
Compliance
cULus Listed 1598 Luminaire
cULus Listed for Damp Location
cULus Listed for Wet Location, with
select trims
RoHS compliant
Air-Tite code compliant. Certified
under ASTM E283; not exceeding
2.0 cfm (0.944 L/s) air leakage rate
tested at a 1.57 psf (75 Pa) pressure
differential
FOR USE IN EXISTING
CEILINGS
FOR USE IN
NON-INSULATED CEILINGS
OR
INSULATED CEILINGS BUT
INSULATION MUST BE
KEPT 3” FROM ALL SIDES
OF FIXTURE
TD518104EN
2/29/2016
Special Features
Quick Connect™ push wire nuts
Air-Tite™ code compliant
4-1/4"
[108mm]
5"
[127mm]
11-1/2"
[292mm]
4-5/8"
[116mm]
Ceiling opening to match
template supplied
4-1/4"
[108mm]
5"
[127mm]
11-1/2"
[292mm]
4-5/8"
[116mm]
Ceiling opening to match
template supplied