Specification
HALO
®
Catalog #
Type
Project
Comments
Date
Prepared by
E4TATSB
4” Non-Insulated Ceilng
AIR-TITE Recessed
Housing with Adjustable
Socket Bracket
4” Trims
Dimensions
Specification Features
Description
The E4TATSB is a Non-IC Air-Tite
TM
housing optimized and listed for
EISA compliant tungsten-halogen lamps, CFL and LED lamps, as well
as incandescent. Housing features an adjustable socket bracket, and is
suitable for residential or commercial applications. Installation in non-
insulated ceilings with Air-Tite code compliant construction. If insulation
is present it must be kept 3” from all sides of the housing. May be
retrofit with compatible Halo LED lighting systems.
Housing
•
Die-formed CRS
Junction Box
•
Seven conduit knockouts are uniform
1/2” size with true pry-out slots
•
Four pry-outs with integral strain
relief simplify “NM” non-metallic
sheathed cable installation
•
Three quick connect wire connectors
included
Plaster Frame
•
Housing is secured in plaster frame
with spring barbs.
•
The housing can be removed from
the plaster frame to provide access
to the junction box.
•
Air-Tite gasket pre-installed on
plaster frame.
Includes:
All Nail!™
•
Integral precisely positioned nail for
engineered and natural framing
•
Mini-foot leveling flange
•
Integral T-Grid Clip, no accessory
clips required
Quick Connect™
•
(3) Push wire nuts included, for
speed & reliability
•
Clear caps for wire connection
visibility
Air-Tite™ code compliant
•
ASTM E283 compliant
Socket
•
Adjustable position bracket with
porcelain socket and nickel plated
brass screw shell provides flexibility
in lamp positioning.
Thermal Protector
•
Self resetting thermal protector
deactivates fixture if overheating
occurs due to improper lamping or
misapplied insulation.
Trims
•
Halo Fit-All concept offers
multiple trim options in a variety
of design styles, and functional
beam distributions to control
beam angle and lumen delivery in
accommodating various lamp types.
Compliance
•
cULus Listed 1598 Luminaire
•
cULus Damp Location Listed
•
cULus Listed for Wet Location,
covered ceiling, with select trims
•
RoHS Compliant
•
Air-Tite code compliant. Certified
under ASTM E283; not exceeding
2.0 cfm (0.944 L/s) air leakage rate
tested at a 1.57 psf (75 Pa) pressure
differential
FOR USE IN
NON-INSULATED CEILINGS
OR
INSULATED CEILINGS BUT
INSULATION MUST BE
KEPT 3” FROM ALL SIDES
OF FIXTURE
TD518105EN
2/29/2016
Special Features
All-Nail!™ bar hangers
Quick Connect™ push wire nuts
Air-Tite™ code compliant
4-1/2"
[114mm]
Ceiling opening
5"
[127mm]
1/2"
[13mm]
8"
[203mm]
5-1/4"
[133mm]
4-1/2"
[114mm]
Ceiling opening
5"
[127mm]
1/2"
[13mm]
8"
[203mm]
5-1/4"
[133mm]