Specification

HALO
®
Catalog #
Type
Project
Comments
Date
Prepared by
E4TATSB
4” Non-Insulated Ceilng
AIR-TITE Recessed
Housing with Adjustable
Socket Bracket
4” Trims
Dimensions
Specification Features
Description
The E4TATSB is a Non-IC Air-Tite
TM
housing optimized and listed for
EISA compliant tungsten-halogen lamps, CFL and LED lamps, as well
as incandescent. Housing features an adjustable socket bracket, and is
suitable for residential or commercial applications. Installation in non-
insulated ceilings with Air-Tite code compliant construction. If insulation
is present it must be kept 3” from all sides of the housing. May be
retrofit with compatible Halo LED lighting systems.
Housing
Die-formed CRS
Junction Box
Seven conduit knockouts are uniform
1/2” size with true pry-out slots
Four pry-outs with integral strain
relief simplify “NM” non-metallic
sheathed cable installation
Three quick connect wire connectors
included
Plaster Frame
Housing is secured in plaster frame
with spring barbs.
The housing can be removed from
the plaster frame to provide access
to the junction box.
Air-Tite gasket pre-installed on
plaster frame.
Includes:
All Nail!™
Integral precisely positioned nail for
engineered and natural framing
Mini-foot leveling flange
Integral T-Grid Clip, no accessory
clips required
Quick Connect™
(3) Push wire nuts included, for
speed & reliability
Clear caps for wire connection
visibility
Air-Tite™ code compliant
ASTM E283 compliant
Socket
Adjustable position bracket with
porcelain socket and nickel plated
brass screw shell provides flexibility
in lamp positioning.
Thermal Protector
Self resetting thermal protector
deactivates fixture if overheating
occurs due to improper lamping or
misapplied insulation.
Trims
Halo Fit-All concept offers
multiple trim options in a variety
of design styles, and functional
beam distributions to control
beam angle and lumen delivery in
accommodating various lamp types.
Compliance
cULus Listed 1598 Luminaire
cULus Damp Location Listed
cULus Listed for Wet Location,
covered ceiling, with select trims
RoHS Compliant
Air-Tite code compliant. Certified
under ASTM E283; not exceeding
2.0 cfm (0.944 L/s) air leakage rate
tested at a 1.57 psf (75 Pa) pressure
differential
FOR USE IN
NON-INSULATED CEILINGS
OR
INSULATED CEILINGS BUT
INSULATION MUST BE
KEPT 3” FROM ALL SIDES
OF FIXTURE
TD518105EN
2/29/2016
Special Features
All-Nail!™ bar hangers
Quick Connect™ push wire nuts
Air-Tite™ code compliant
4-1/2"
[114mm]
Ceiling opening
5"
[127mm]
1/2"
[13mm]
8"
[203mm]
5-1/4"
[133mm]
4-1/2"
[114mm]
Ceiling opening
5"
[127mm]
1/2"
[13mm]
8"
[203mm]
5-1/4"
[133mm]