Technical Specifications

D E S I G N F E A T U R E S
D E S C R I P T I O N
The All-Pro EI4700 and EI4700AT are designed for sloped ceiling
installations for ceilings from 2/12 to 6/12 pitch. The socket aiming
mechanism allows the lamp to be aimed straight down regardless of
ceiling pitch. EI4700AT is sealed and gasketed to limit airflow
between plenum and heated or air conditioned areas.
H o us i n g
Integral thermal protector
guards against improper
lamping.
EI4700AT Housing has
AIR-TITE gasket pre-installed
for ASTM-E283 compliance.
Double wall housing
construction. Door in outer
housing allows junction box
access from below ceiling.
Exclusive socket aiming
mechanism swivels and
rotates to properly align lamp.
Slope indicator provides quick
and consistent lamp settings
(factory set for 3/12 slope).
J u n c t i o n B o x
Listed for through branch
circuit wiring. Positioned to
accommodate straight conduit
runs. Seven conduit knockouts
are uniform 1/2" size with true
pryout slots. Four “NM” cable
pryouts with integral strain relief
also included. Quick-connect
wiring connectors included.
B a r H a n g e r s
All-Nail™ preinstalled bar
hangers adjust up to 24” wide.
The All-Nail™ bar hanger also
includes a preinstalled nail that
penetrates standard and
engineered lumber. The Mini-
leveling flange aligns bar hangers
on bottom of the joist. Score lines
allow bars to be shortened for
use in tight joist spaces.
And, the integral T-bar clip snaps
onto T-grid ceilings - no
additional clips required.
I n s t a l l a t i o n F e a t u r e s
7-1/8" Height allows use in
2"x 8" construction.
One piece seamless baffle
presents a clean finished
appearance.
L i s t i n g s
UL/cUL Listed 1598 Luminaire
UL/cUL Listed for Damp
Location
UL/cUL Listed for Feed
Through
UL/cUL Listed for Direct
Contact with Insulation and
combustible material
EI4700AT also meets the
following Air-Tite™
requirements:
• Washington State Energy Code
• State of California Title 24 Low
Efficacy Luminaire IC and AT
requirement
• International Energy
Conservation Code (IECC)
• New York State Energy
Conservation Construction
Code (NY-ECCC)
• Certified Under ASTM-E283
O R D E R I N G I N F O R M A T I O N
S A M P L E N U M B E R : E I 4 7 0 0 - E R T 4 9 8 0 W H T
O r d e r h o u s i n g a n d t r i m s e p a r a t e l y .
EI4700=6˝ IC Slope Ceiling Housing
EI4700AT=6˝ IC Slope Ceiling
Housing, AIR-TITE™
H o u s i n g
Baffle
ERT4980WHT=High Gloss
Appliance White Trim with
White Baffle
T r i m s
Catalog #
Project
Comments
Prepared by
Type
Date
EI4700
I C S L O P E C E I L I N G
H O U S I N G
EI4700AT
I C A I R - T I T E
S L O P E C E I L I N G
H O U S I N G
ADV100776
rev 6/13/10
6-3/4"
[171mm]
7-1/8"
[181mm]
1/2"
[13mm]
10-1/2"
[267mm]
10"
[254mm]
14-3/4"
[375mm]
5-1/4"
[133mm]
ALL-PRO
www.cooperlighting.com