Product Brochure
Specifications, compliances and dimensions subject to change without notice
6
INCH
HALO Halo Recessed Catalog - 6" Recessed Downlighting
360
H645IC
E26 Screw Base H645IC Slope Housing
Compatible Trims
78
170
455
456
H645IC
6" IC, Air-Tite, New Construction Slope Housing, 120V
Designed for sloped ceiling installations for ceilings from
2/12 to 12/12 pitch. The socket aiming mechanism allows
the lamp to be aimed straight down in accordance with of
ceiling pitch (2/12 to 12/12). H645IC is designed for use in
insulated ceilings where the housing will be in direct contact
with insulation*. H645IC is Air-Tite gasketed to limit airflow
between conditioned spaces and unconditioned areas.
Features
Housing
Aluminum double wall housing construction
Plaster Frame
Housing adjusts in plaster frame to accommodate
up to 1" ceiling thickness. Galvanized steel construction.
Plaster frame features include:
•
Regressed locking screw for securing hanger bars
•
Cutouts for easily crimping hanger bars in position
•
Halo name embossed on plaster frame. The housing
may be removed from plaster frame to provide
access to the junction box.
•
Pre-installed Air-Tite
™
ready ceiling contact gasket
Includes:
•
Got Nail!
™
bar hangers (Details Pg. 13)
•
Slide-N-Side
™
junction box wire traps (Details Pg. 13)
•
Pass-N-Thru
™
bars (Details Pg. 13)
•
Air-Tite
™
code compliant (Details Pg. 13)
Socket
Exclusive socket aiming mechanism swivels and rotates
to properly align lamp. Lamp socket and trim can be
adjusted 20° laterally for compound slope ceiling or to
compensate for off axis aiming. Shipping insert protects
socket from overspray.
Integral Thermal Protector
Integral thermal protector guards against improper lamping
Compliance
•
cULus Listed 1598 luminaire
•
cULus Listed damp location
•
cULus Listed for wet location,
covered ceiling, with select trims
•
cULus Listed for feed through
•
cULus Listed for direct contact with
insulation and combustible material*
•
Air-Tite code compliant. Certified under ASTM E283;
not exceeding 2.0 cfm (0.944 L/s) air leakage rate
tested at a 1.57 psf (75 Pa) pressure differential.
•
Rated for 20W maximum
•
Refer to specification sheets online for additional
compliance information
•
RoHS compliant
*Not to be used in direct contact with spray foam insulation
(Consult NEMA LSD57-2013)
Special Features
Got Nail!
™
bar hangers
Pass-N-Thru
™
bars
Slide-N-Side
™
junction box
Quick Connect
™
push wire nuts
Air-Tite
™
code compliant
1/2"
[1
3mm]
7-3/8"
[187mm]
6-1/2"
[165mm]
Ceiling opening
9-1/2"
[241mm]
13"
[330mm]
1/2"
[13mm]
7-3/8"
[187mm]
6-1/2"
[165mm]
Ceiling opening
9-1/2"
[241mm]
13"
[330mm]
12/12
11/12
10/12
9/12 45°
8/12 42.5°
7/12 39.8°
6/12 36.8°
5/12 33.5°
4/12 30°
3/12 26.5°
2/12 22.5°
18.5°
14°
10°
For proper
slope aiming
install with
junction box
in upward
position
Improper
Install