Technical Specifications

SLD4058xxWH
SLD4059xxWH
HALO
ORDERING INFORMATION
SAMPLE NUMBER: SLD405927WH SLD4TRMSN
Junction Box Installation: Order junction box separately, as supplied by others, to complete installation.
Recessed Installation: Order Halo recessed housing separately to complete installation.
Models Color Rendering Index Color Temperature (CCT) Finish Accessories
SLD405= 4” Surface LED Downlight, 120V 8=80 CRI
9=90 CRI
27=2700K
30=3000K
35=3500K
40=4000K
WH=White
Designer Trims
Fit over the SLD4 for a designer nish
SLD4TRMSN=4” SLD Satin Nickel
SLD4TRMTBZ=4” SLD Tuscan Bronze
SLD4TRMWH=4” SLD White (paintable)
J-Box Spacer Extension Ring
Add 15/16” depth when SLD driver cannot t into installed
junction box
SLD4EXT=4” Surface LED J-Box Extender, 7.75” O.D.
RAD Adapters
When junction box is mounted at on a ceiling or beam
surface (not recessed in ceiling)
SLD4RAD=4” SLD Round Surface J-Box Adapter,
6.15” O.D. (For 4-inch round or octagon junction boxes)
Spare Parts
SLD4ACCKIT=4” Accessory Parts Replacement Kit
(Screwbase adapter, torsion springs, friction blades)
SLD4BRKT=4” Junction Box Bracket & Screws
Refer to SLD Accessories specication sheet for further
information.
DIMENSIONS
SLD4058xxWH
80CRI
2700K, 3000K, 3500K,
and 4000K
SLD4059xxWH
90CRI
2700K, 3000K, 3500K,
and 4000K
4” Surface LED
Downlight
Suitable for
ceiling or wall
electrical junction boxes
Suitable for
4” recessed
housing retrofit
(IC, Non-IC & AIR-TITE™)
LED DRIVER
Driver is a 120V input high
efficiency, dimmable electronic
power supply providing DC power
to the LED array
Driver features high power factor,
low THD, and has integral thermal
protection in the event of over
temperature or internal failure.
Driver is replaceable if it should be
required
DIMMING
• Designed for continuous dimming
capability to nominally 5% with
many 120V Leading Edge (LE)
and Trailing Edge (TE) phase
control dimmers. Dimming to 5%
is best assured using dimmers
with low end trim adjustment.
Consult dimmer manufacturer for
compatibility and conditions of
use. (Note some dimmers require
a neutral in the wallbox.)
COMPLIANCE
cULus Listed ceiling and w
all
cULus Damp Location listed
ceiling and wall
cULus Wet Location Listed, ceiling
only (shower rated)
Suitable for use in closets,
compliant with NFPA® 70, NEC®
Section 410.16 (A)(3) and 410.16
(C)(5)
SLD may be used in compatible
electrical junction boxes in direct
contact with insulation including
spray foam insulation
May be installed in IC recessed
housings in direct contact with
insulation (Not for use in recessed
housings in direct contact with
spray foam insulation. Refer to
NEMA LSD 57-2013)
UL Classified when used in
retrofit with listed housings
(See Housing Compatibility)
EMI/RFI: meets FCC 47CFR P
art 15
Class B limits, and is suitable for
use in residential and commercial
installations
Air
tight certified per ASTM E283
(not exceeding 2.0 CFM under 57
Pascals pressure difference)
90 CRI: Can be used to comply
with California Title 24 High
Efficacy requirements. Certified
to California Title 20 Appliance
Efficiency Database.
80 CRI: Can be used to comply
with California
Title 24 Non-
Residential Lighting Controls
requirements as a LED luminaire.
• Can be used for International
Energy Conservation Code (IECC)
and Washington State Energy
Code high efficiency luminaire
compliance
• ENERGY STAR® Certified
luminaire - consult ENERGY
STAR® Certified Product List
Contains no mercury or lead and
R
oHS compliant.
Photometric testing in accordance
with IES LM-79
Lumen maintenance projections
in accordance with IES LM-80 and
TM-21
6”
[152mm]
.7”
[17.42mm]
.8”
[20.20mm]
6”
[152.65mm]