Spec Sheet

57"
1448mm
27"
686mm
19"
483mm
36 11/16"
931mm
8"
203mm
27 5/16"
694mm
3"
76mm
37"
940mm
14 9/16"
371mm
10"
254mm
O
A
C
B
B
1/2" O (6)
(13mm)
O
12"
305mm
B.C.
O
14"
356mm
29"
737mm
halseytaylor.com
HALSEY TAYLOR, 2222 Camden Court, Oak Brook, IL 60523
Printed in the U.S.A.
®
Page 2
A = 3/8” O.D. UNPLATED COPPER TUBE CONNECT
SHUT OFF VALVE BY OTHERS
B = ACCESS PANEL (8” x 10”)
C = REMOVABLE BOTTOM COVER
Endura II™Outdoor Tubular
Bottle Filling Station
MODEL 4410BF
TOP VIEW
OPERATING PRESSURES:
Supply water 20 – 105 psi maximum
* ADA Requirement
*
BACK VIEW
MOUNTING INSTRUCTIONS and
PLUMBING CONNECTIONS
Refer to diagrams for plumbing rough-in. Provide solid,
well-drained smooth, at, nished surface to mount
pedestal fountain (concrete pad recommended) with
adequate support (300 lb. load minimum). To secure
unit, use (6) 3/8” minimum fasteners (not provided).
A service supply stop must be installed at the
fountain inlet line.
Trap and service stop not included.
Position pedestal over plumbing and secure base to
fasteners. Remove access panels and connect supply
and water lines. Turn on water supply and check for
leaks. Refer to owner’s manual for detailed instructions.
Reassemble access panels to pedestal.