Spec Sheet

O 12"
305mm
O 1/2" (6)
13mm
O 14"
356mm
8"
203mm
27 1/4"
6
92mm
10"O
254mm
B
1-1/4"
DRAIN
22 3/4"
578mm
A
29"
737mm
19"
483mm
27"*
686mm
33 5/16"
846mm
2 7/8"
73mm
34 11/16"
882mm
C
halseytaylor.com
HALSEY TAYLOR, 2222 Camden Court, Oak Brook, IL 60523
Printed in the U.S.A.
®
Page 2
A = 3/8” O.D. UNPLATED COPPER TUBE CONNECT
SHUT OFF VALVE BY OTHERS
B = ACCESS PANEL (8” x 10”)
C = REMOVABLE BOTTOM COVER
OPERATING PRESSURES:
Supply water 20 – 105 psi maximum
TOP VIEW
* ADA Requirement
SIDE & FRONT VIEWSBACK VIEW
Endura II™ Outdoor Tubular
Single Arm Fountain
MODEL 4410
MOUNTING INSTRUCTIONS and
PLUMBING CONNECTIONS
Provide solid, well-drained surface to mount pedestal
fountain (concrete pad recommended) with adequate
support (300 lb. load minimum). (6) 3/8” minimum
fasteners (not included) should be attached rmly to
mounting surface in order to secure unit. (Refer to
rough-in diagram)
Locate and install plumbing through ground as required.
NOTE: Unit is not furnished with service valve.
Position pedestal over plumbing and secure base to
fasteners. Remove access panels and connect supply
and water lines. Turn on water supply and check for
leaks. Reassemble access panels to pedestal.
Trap and service stop not included.