Spec Sheet
6 9/16"
167mm
30"
762mm
10"
254mm
O
64"
1626mm
19"
483mm
44"
1118mm
14 9/16"
371mm
29"
737mm
27"
686mm
33 5/16"
847mm
10"
254mm
O
B
A
A
1-1/2" DRAIN
34 11/16"
881mm
ORIFICE
HEIGHT
O
10"
254mm
3"
76mm
*
A
8"
203mm
FRONT & SIDE VIEWS
halseytaylor.com
HALSEY TAYLOR, 2222 Camden Court, Oak Brook, IL 60523
Printed in the U.S.A.
®
Page 2
MOUNTING INSTRUCTIONS and
PLUMBING CONNECTIONS
Provide solid, well-drained surface to mount pedestal
fountain (concrete pad recommended). Mount on a
smooth, at, nished surface with adequate support
(300 lb. load minimum). Secure unit with (8) 3/8” minimum
fasteners (not included). Refer to rough-in. Should be
attached rmly to mounting surface in order to secure unit.
Modied low stream height bubbler for pet fountain.
Locate and install plumbing through ground as required.
NOTE: Unit is not furnished with service valve.
Position pedestal over plumbing and secure base to
fasteners. Remove access panels and connect supply
and water lines. Turn on water supply and check for leaks.
Reassemble access panels to pedestal.
Trap and service stop not included.
A = 3/8” O.D. UNPLATED COPPER TUBE CONNECT
SHUT OFF VALVE BY OTHERS
B = ACCESS PANEL (8” x 10”)
C = REMOVABLE BOTTOM COVER
Endura II™ Outdoor Tubular
Bottle Filling Station
MODEL 4420BF1UDB
TOP VIEW
OPERATING PRESSURES:
Supply water 20 – 105 psi maximum
* ADA Requirement
26"
660mm
O
14"
356mm
(2 PL)
22"
559mm
8 - O.500" HOLES
EQUALLY SPACED ON
TWO
O12.00" B.C.