Spec Sheet

FINISHED FLOOR
B
A
1-1/2" DRAIN
(38mm)
C
8"
203mm
30"
762mm
64"
1626mm
23 1/8"
587mm
27"
686mm
33 5/16"
847mm
34 11/16"
881mm
2 7/8"
73mm
19"
483mm
44"
1118mm
14 9/16"
371mm
3"
76mm
10"
254mm
O
*
halseytaylor.com
HALSEY TAYLOR, 2222 Camden Court, Oak Brook, IL 60523
Printed in the U.S.A.
®
Page 2
MOUNTING INSTRUCTIONS and
PLUMBING CONNECTIONS
Provide solid, well-drained surface to mount pedestal
fountain (concrete pad recommended) with adequate
support (300 lb. load minimum). (6) 3/8” minimum
fasteners (not included) should be attached rmly to
mounting surface in order to secure unit. (Refer to rough-in
diagram)
Locate and install plumbing through ground as required.
NOTE: Unit is not furnished with service valve.
Position pedestal over plumbing and secure base to
fasteners. Remove access panels and connect supply
and water lines. Turn on water supply and check for leaks.
Reassemble access panels to pedestal.
Trap and service stop not included.
A = 3/8” O.D. UNPLATED COPPER TUBE CONNECT
SHUT OFF VALVE BY OTHERS
B = ACCESS PANEL (8” x 10”)
C = REMOVABLE BOTTOM COVER
ENDURA II™ Outdoor Tubular
Bottle Filling Station
MODEL 4420BF1U
TOP VIEW
OPERATING PRESSURES:
Supply water 20 – 105 psi maximum
FRONT & SIDE VIEWS
* ADA Requirement
1/2" O (6 PL)
(13mm)
O
12"
305mm
B.C.
O
14"
356mm
29"
737mm