Spec Sheet

FINISHED FLOOR
B
A
1-1/2" DRAIN
(38mm)
C
8"
203mm
30"
762mm
10"
254mm
O
2 7/8"
73mm
23 1/4"
590mm
40 5/16"
1025mm
19"
483mm
27"
686mm
37"
940mm
14 9/16"
371mm
3"
76mm
57"
1448mm
41 11/16"
1059mm
*
O
14"
356mm
O
12"
305mm
B.C.
O
1/2"
13mm
(6 PL)
29"
737mm
halseytaylor.com
HALSEY TAYLOR, 2222 Camden Court, Oak Brook, IL 60523
Printed in the U.S.A.
®
Page 3
A = 3/8” O.D. UNPLATED COPPER TUBE CONNECT
SHUT OFF VALVE BY OTHERS
B = ACCESS PANEL (8” x 10”)
C = REMOVABLE BOTTOM COVER
MOUNTING INSTRUCTIONS and
PLUMBING CONNECTIONS
Provide solid, well-drained surface to mount pedestal
fountain (concrete pad recommended) with adequate
support (300 lb. load minimum). (6) 3/8” minimum
fasteners (not included) should be attached rmly to
mounting surface in order to secure unit. (Refer to rough-in
diagram)
Locate and install plumbing through ground as required.
NOTE: Unit is not furnished with service valve.
Position pedestal over plumbing and secure base to
fasteners. Remove access panels and connect supply
and water lines. Turn on water supply and check for leaks.
Reassemble access panels to pedestal.
Trap and service stop not included.
Endura II™Outdoor Tubular
Bottle Filling Station
MODEL 4420BF1L
OPERATING PRESSURES:
Supply water 20 – 105 psi maximum
TOP VIEW
* ADA Requirement