Specification Sheet

Printed in the U.S.A.
77002200
TTwwoo--SSttaattiioonn
DDrriinnkkiinngg FFoouunnttaaiinn
(CONTINUED)
MMOOUUNNTTIINNGG IINNSSTTRRUUCCTTIIOONNSS
Refer to diagrams for rough-in of plumbing.
Wall hanger is included with product. For
wall support required locations see installation
instructions provided with fountain. Mount wall
hanger brackets to the wall per the installation
instructions. Hang fountain and attach to wall.
Water service line and waste line are to be
assemble as required. Final check for leaks and
correct functions of fountain should be made.
(For details see the installation instructions.)
CCAAUUTTIIOONN –– FFoouunnttaaiinn mmuusstt bbee sseeccuurreellyy
bboolltteedd ttoo wwaallll
OOPPEERRAATTIINNGG PPRREESSSSUURREESS
Supply water-105 psi maximum
NOTE: Trap and service stop not included.
A service stop must be installed at the
fountain inlet line.
11"
279mm
6 1/2"
165mm
2"
51mm
2"
51mm
C
L
C
L
31"
787mm
14"
356mm
12"
305mm
12"
305mm
3"
76mm
2" 51mm
3/4"
19mm
9 1/4"
235mm
2"
51mm
2"
51mm
15"
381mm
REMOVABLE
BOTTOM
PANEL
22-1/4" 565mm FOR 28" RIM HEIGHT
28-1/4" 718mm FOR 34" RIM HEIGHT
34-1/4" 870mm FOR 40" RIM HEIGHT
1-1/2" I.P.S. WASTE STUBBED
2" (51mm) FROM WALL
3/8" I.P.S. COLD WATER SUPPLY STUB
1" (25mm) OUT FROM WALL
20" 508mm FOR 28" RIM HEIGHT
26" 660mm FOR 34" RIM HEIGHT
32" 813mm FOR 40" RIM HEIGHT
C
L
15"
381mm
7 1/2"
190mm
TOP VIEW
FRONT VIEW