Instructions / Assembly

Page 5 98945C (Rev. E - 03/18)
HACFSCDBL*E HACFSCDDBL*E HACFSCDDBLR*E HACFSCWFDBL*E HACFSCWFDDBL*E
HAC8FSCBLQ*1F HAC8FSCBLRQ*1F HAC8FSCWFBL*1F
COOLER BACK
SUPPORT DE SUSPENSION
ARRIÈRE DU REFROIDISSEUR
HANGER BRACKET
FIJADOR DE SUSPENSIÓN
SUPPORT DE SUSPENSION
PUSH BAR MECHANISM
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN
AUTHORIZED SERVICE PERSON
HANGER BRACKETS & TRAP
INSTALLATION
1) Remove hanger brackets fastened to back of cooler by removing one
(1) screw.
2) Mount the hanger brackets and trap as shown in Figures 2 or 3.
NOTE: Hanger Brackets MUST be supported securely. Add xture sup-
port carrier if wall will not provide adequate support.
IMPORTANT:
4 1/8 in. (105mm) dimension from wall to centerline of trap must be
maintained for proper t.
Anchor hanger securely to wall using all ve (5) 5/16" dia.
mounting holes.
3) Install straight valve for 3/8" O.D. tube.
INSTALLATION OF COOLER
4) Hang the cooler on the hanger bracket. Be certain the hanger
bracket is engaged properly in the slots on the cooler back as
shown in Fig. 5.
5) Loosen the two (2) screws holding the lower front panel at the
bottom of cooler base and two (2) screws at the top. Remove the
front panel and set aside.
6) Connect water inlet line--See Note 4 of General Instructions.
7) Remove the slip nut and gasket from the trap and install them on
the cooler waste line making sure that the end of the waste line
ts into the trap. Assemble the slip nut and gasket to the trap and
tighten securely.
START UP
Also See General Instructions
8) Stream height is factory set at 45-50 PSI. If supply pressure varies
greatly from this, readjust stream height to approximately 1-1/2"
(38mm) above the bubbler guard by turning adjustment screw, ac-
cessible by removing front push panel. Item No. 16 (see Fig. 4 & 6).
9) Replace the front panel and secure by retightening four (4) screws.
10) If a taste, odor or sediment problem is prevalent, try installing our
water lter module.
FIG. 4
CORRECT STREAM HEIGHT
FIG. 5
FIG. 6
LEGEND
A) Note: Water ow direction
B) Adjust this screw to eliminate mechanism “Free Play” or continuous ow
from bubbler conditions. (See ADJUSTMENT PROCEDURE)
C) Stream height adjustment (see note #8)
Water Valve Mechanism - ADJUSTMENT PROCEDURE:
- Turn adjustment screw (Item 11) “Counter-Clockwise” until water ow from bubbler starts.
- Turn adjustment screw “Clockwise” until water ow stops, THEN turn an additional 1/2 turn.
NOTE: Adjustments stated above are viewed from underneath unit (bottom side of
dispenser panel Item 40)
NOTE: If continuous ow occurs at the end of the compressor cycle, turn cold control
(Item 29) counterclockwise 1/4 turn.
14
4
3
4
16
3
3
4
2
C
3
4
15
3
3
4
2
4
8
49
40
2
35
41
35
35
A
11 - B
2
39
26