Specification
Printed in the U.S.A.
Barrier-Free Cooler
(CONTINUED)
MOUNTING HEIGHT
Mounting height recommended 28
1
/
2" from
basin to floor. May be mounted at any desired
height. Check local codes.
MOUNTING INSTRUCTIONS
Mount trap and install service stop to building
supply line. Anchor hanger bracket securely to
wall on all sides. To insure proper engaging of
waste line into trap, centerline of trap must be
6
1
/
4" from wall face. Remove slip nut and gasket
from trap and install on waste line tube. Hang
cooler on bracket and engage waste line tube
into trap inlet. Centerline height of waste outlet
will vary from floor line depending on mounting
height. Install
3
/
8 supply tube to in-line strainer.
Secure bottom of cooler to wall using holes
provided.
Trap and service stop not included.
OPERATING PRESSURES:
Supply water - 105 psi maximum
ELECTRICAL
Furnished with plug-in, 3-wire grounding type
service cord. Standard 120 volt, 60 Hz, single
phase. Install 120-volt receptacle, rated at
15-amp minimum, to receive 3-wire parallel
blade grounding type male plug.
FINISHED FLOOR
*
HANGER BRACKET
E
F
RIM HEIGHT
ORIFICE HEIGHT
5/16" (8mm) DIA. (5 HOLES)
A
D
B
E
C
12 5/16"
313mm
1 3/8"
35mm
1 3/8"
35mm
5 3/4"
146mm
5 3/4"
146mm
L
C
27"
686mm
31 7/8"
810mm
33"
838mm
18 5/8"
473mm
2 9/16"
65mm
13 7/8"
352mm
18 3/8"
467mm
21 3/8"
543mm
25"
635mm
31"
787mm
2 1/2"
64mm
3 1/2"
89mm
4 1/2"
114mm
2 7/16"
63mm
5"
127mm
10"
254mm
11/16"
18mm
2 9/16"
65mm
7 1/4"
185mm
6 1/4"
159mm
8"
203mm
1 1/2"
38mm
4 9/16"
116mm
6 3/4"
172mm
A. RECOMMENDED WATER SUPPLY LOCATION. 3/8" O.D. UNPLATED COPPER TUBE CONNECT STUB
1-1/2" (38 mm) OUT FROM WALL SHUT OFF VALVE NOT FURNISHED.
B. RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4" O.D. DRAIN
C. 1-1/4" TRAP NOT FURNISHED
D. ELECTRICAL SUPPLY (3) WIRE RECESSED BOX
E. INSURE PROPER VENTILATION BY MAINTAINING 6" (152 mm) MIN. CLEARANCE FROM CABINET LOUVERS TO WALL
F. 7/16" BOLT HOLES FOR FASTENING UNIT TO WALL
FRONT VIEW SIDE VIEW
* Adult ADA requirement. 24" (609mm) for Child ADA.
Adjust other measurements accordingly.
HAC8FS-Q ADA,
HACFS-L/R ADA