Use and Care Manual
HACFSCWSD*1F HACFSCWSDNF*1F HAC8FSCWSQ*1F, *3F HAC8FSCWSNFQ*1F, *2F
1000001728 (Rev. B - 11/14) Page 6
TOP COVER
MOUNTING
SCREWS
Fig. 6
Fig. 7
35
7/16” BOLT HOLES FOR
FASTENING UNIT TO WALL
UNIT CENTER LINE
Fig. 9
Fig. 8
BRACKET, WASHERS,
& SCREWS
Bottle Filler Installation Instructions
1) Remove two (2) mounting screws with 5/32” Allen wrench holding top cover to Bottle Filler (See Fig. 7). Remove top cover. Note do not discard mounting
screws, they will be needed to reinstall top cover.
2) Remove wall mounting plate from Bottle Filler. Place wall plate against wall on top of basin. Center the wall plate side to side with the basin. Mark
thesix(6)mountingholeswithapencil(SeeFig.2).
3) Remove wall mounting plate from wall. NOTE: Mounting plate MUSTbesupportedsecurely.Addxturesupportcarrierifwallwillnotprovideadequate
support.
4)Installwallmountingplatetowallusingsix(6)7/16”obroundmountingholes(mountingboltsnotincluded)(SeeFig.6).Useappropriatefastenersfor
your wall type.
5) Feed power cord & 3/8” water line through hole in tower/basin gasket (See Fig 8).
6)Installgasketonbottomofbottlellertowerwithgasketsupportbracket,(2)washers,&(2)screws(SeeFig9).
7) Fish the purple wire (single units) or the purple and yellow wires (two-level units) up through basin hole & hole in gasket.
8) For Single Model installations: Attach the purple wire from cooler to the purple wire on the back of the unit, (Note yellow wire is not used).
8a) For Two-Level model installations: Attach the purple and yellow wires from coolers to the purple and yellow wires on the back of the unit, purple to
purple, yellow to yellow.
9) Lay Bottle Filler on water cooler basin and cut insulation from tube even with bottom of gasket, remove this insulation from the 3/8” tube, but do not discard.
Fish the power cord and waterline through the hole on top of water cooler. NOTE: To prevent scratching the basin place a towel or soft
cloth over the entire basin when working above it.
10) With the power cord, wire(s), and waterline through hole on top of water cooler place Bottle Filler on the three (3) angled tabs protruding from the wall
mountingplate,installedonwall.Makesureroundbossingaskettsinholeofbasin.(SeeFig.10).
11) Once Bottle Filler is installed on wall plate tabs, water line, wire(s) and power cord are installed properly, push top of Bottle Filler toward
wall and line up top cover two (2) holes.
12) Reinstall Top Cover on Bottle Filler (See Fig. 7) with two mounting screws from step 1 above. Caution, do not over tighten screws.
13)Installremainingtubeinsulationtothewaterlinefrombottleller,connectBottleFillerwaterlineinsideofthewatercoolerbyconnectingthe3/8”waterlinetothetee.
14)Installltercartridge,removelterfromcarton,removeprotectivecap,attachltertolterheadbyrmlyinsertingintoheadandrotatinglter
clockwise.NOTE:Ifexistingplumbingroughinlocations(Drain,WaterIn,andElectricSupply)donotallowtheltertobemountedinsidethecoolercabinet
theltercanbeinstalledhorizontallybelowtheunit.Aretrotkitisavailabletomountthelterbeneaththecooler.
15)Turnwatersupplyonandinspectforleaks.Fixallleaksbeforecontinuing.
16) Once unit has been inspected for leaks and any leaks found corrected, plug Bottle Filler and unit into wall. Be sure to reinstall fuse to the circuit or
switch the circuit breaker back to the “ON” position.
17)OncepowerisappliedtoBottleFiller,theGREENLEDlightshouldilluminateshowinggoodlterstatusalongwiththeLCDBottleCounter.
18)Verifyproperdispensingbyplacingcup,hand,oranyopaqueobjectinfrontofsensorareaandverifywaterdispenses.Note:therstinitialdispenses
might have air in line which may cause a sputter. This will be eliminated once all air is purged from the line.
19) Once unit tests out, install Lower Panel back on water cooler(s). Units are now ready for use.