Specification Sheet
20 3/8"
518mm
20 7/16"
519mm
19 3/4"
502mm
17 3/8"
441mm
1 3/16"
30mm
1 3/16"
30mm
8 1/8"
206mm
9 3/8"
238mm
1 1/8"
29mm
3"
79mm
18 3/4"
476mm
4"
102mm
FILTER LOCATION
1/4" O.D. TUBE CONNECT
(CHILLER WATER OUTLET)
3/8" O.D. TUBE CONNECT
(CHILLER WATER INLET)
SHUT OFF VALVE BY OTHERS
BACK WALL LINE
12"
305mm
MINIMUM
DEPTH
FINISHED FLOOR
25 1/4"
642mm
27"
682mm
38 7/8"
988mm
2 7/8"
73mm
25 7/8"
658mm
1-1/4" (32MM)
WASTE TUBE
FURNISHED
3 1/2"
89mm
4 1/2"
117mm
1 1/8"
29mm
11"
279mm
ELECTRICAL
INLET
FINISHED FLOOR
DOUBLE STUD OR 3" (76mm)
BETWEEN MOUNTING FRAMES
IF PLACED NEXT TO ANOTHER
FOUNTAIN OR WALL
32 11/16"
831mm
NOTE - NON-REFRIGERATED MODELS
(WITHOUT CHILLER) REQUIRE 8" (203MM)
MINIMUM DEPTH
NOTE: NON-REFRIGERATED
MODELS (WITHOUT CHILLER)
DO NOT INCLUDE LOUVERS
ACTIVATION 
 SENSOR
40"
1016mm
4 1/2
114mm
18 3/4"
476mm
5 1/8"
130mm
BACK OF WALL TO
BE 12" (305mm)
 MIN DEPTH
8"
203mm
TO FLOOR LINE
FLOOR LINE
WOOD OR STEEL FRAME SHOWN
(NOT PROVIDED)
ELECTRICAL INLET
LOCATION ON CHILLER
1"
25mm
CHILLER SHELF
P/N 27638C
  HOOK RODS (2)
P/N 101567443730
SCREWS OR BOLTS
(NOT PROVIDED)
 5/16" SCREWS OR BOLTS
(10 REQ'D-NOT PROVIDED)
FRAME
MFWS100
DOUBLE STUD OR 3 INCHES (76 mm) 
BETWEEN MOUNTING FRAMES 
IF PLACED NEXT TO ANOTHER 
FOUNTAIN OR WALL
®
Printed in the U.S.A.
MOUNTING INSTRUCTIONS:
Refer to diagrams for rough-in of plumbing.  Install 
mounting frame into wall per the installation 
instructions. Hang fountain panel over the wall 
plate  assembly.    Attach  fountains  to  wall  plate 
assembly. Water service line and waste line are to 
be  assembled  as  required.    Final  check  for  leaks 
and  correct  functions of  fountain  should  be  made.  
(For details see the installation instructions.)
NOTE:  A service stop (not included) must be installed at 
  the fountain inlet line.
NOTE:  P-Trap (not supplied) to be installed per local   
  building code.
NOTE:  For wall support required locations see installation 
  instructions provided with panel and fountains.
CAUTION - Fountain must be securely bolted   
to wall.
OPERATING PRESSURES:
Supply water - 105 psi maximum
Minimum 40 psi supply line pressure required in special 
circumstances where  both sides  of bi-level  are in  use 
simultaneously to ensure adequate stream height. Use 
of water lter in this situation is not recommended.
ELECTRICAL
Hydroboost
®
 station equipped with electric cord and 
three-prong  molded  rubber  plug  for  use  with  15-
amp minimum receptacle. For the cooling unit, a 
junction  box  for  a  (3)  wire,  10  amp  branch  circuit  is 
provided. Rated at 115 volt, 60 Hz, single phase.
Specications and measurements are subject to change without notication.
Please visit halseytaylor.com for most current version.
Satisfying Thirsts Since 1912
FILTERED
HYDROBOOST™
 Job Name: ______________________________
 Date: __________________ Qty. ____________ 
 Contact Info (Name, Phone, Email): __________
________________________________________
________________________________________
 Approval: _______________________________
TOP & SIDE VIEWS
FRONT VIEW 
WALL LAYOUT