Installation Sheet
0000001032 (Rev. H - 03/19)
OVLSEBPWSI_NF OVLSEBPWSI_WF
Page 4
Figure 4 - Upper Panel Installation
Figure 5 - Fountain Installation
26
Reset
Switch
33, 34, 35, 36, 37
20
10
17
8. Install fountains with (8) 5/16-18 HHMS & (8) 5/16-18 nuts
(provided) (Fig. 5). Connect the ¼” water lines from each
fountain to the remaining openings on the tee at the remote
chiller (cut lines to t as needed).
9. Attach waste tubes (1-1/4” O.D.) to 1-1/4” O.D. slip trap.
Trap on the bottle ller side must be 1-1/2” O.D. (provided by
others).
10. Make nal water supply connections.
11. These products are designed to operate on 20-105 PSI
supply line pressure. If inlet pressure is above 105 PSI, a
pressure regulator must be installed in the supply line.
(Caution: Any damage caused by connecting these products
to a supply line with pressure lower than 20 PSI or higher
than 105 PSI IS NOT covered under warranty.)
12. Make electrical connections to the bottle ller and remote
chiller. The LCD Bottle counter should illuminate.
13. Verify proper dispensing from the bottle ller by placing a cup,
hand or any opaque object in front of sensor area and verify
water dispenses. Note: the rst initial dispenses might have air
in the line which may cause a sputter. This will be eliminated
once all air is purged from the line. A steady stream of water
assures all air is removed. The sensor has a 20 second maxi
mum ON time. It may be necessary to step away from the
beam a few times to purge all air. Check for leaks.
14. Check stream height from bubbler. Stream height is factory set
for 35 PSI supply. If supply pressure varies greatly from this,
remove push arm (Item 7 - Fig. 8) and adjust the screw on
the regulator (Item 19 - Fig. 7). To remove push button,
remove bottom plate (Item 8). Clockwise adjustment will raise
stream height and counterclockwise movement will lower
stream height. For best adjustment stream should hit basin
approximately 6-1/2” from the bubbler. Reassemble the push
bar (Fig. 8).
15. Install the cover plates.
16. Optional: Mount optional panels. Install bracket per rough-
in, slide tongue of panel under edge of already installed panel.
Tighten screws.
Back
Panel
2
3
5
18
4
9
NOTE:
When installing replacement bubbler and pedestal
(Fig. 6), tighten locknut only to hold parts snug in posi-
tion. Do Not overtighten.
Figure 6 - Bubbler Detail
1
Locknut
20