SECTION4 Inputs & Outputs
The ECU has a number of optional inputs and outputs other than the available injection and
ignition channels. These are:
OUTPUTS:
- Idle Speed Control
- Auxiliary Out (Aux Out)
- Digital Output (Digital Out 1-2)
- Pulse Width Modulated Output (PWM 1-4)
INPUTS:
- O
2
Closed Loop Control
- Auxiliary In (Aux In)
All the inputs and outputs have different functions:
- The Idle Speed control outputs can only be used to drive a stepper motor
idle control valve.
- For the Aux Out functions refer to 4.2.4 The In/Out Set-up Page, p39
- The Digital Outputs and PWM Outputs are functionally described in the
table below.
- The O
2
Closed Loop Control uses the input signal on the O2 pin for O2
corrections only.
- For the Aux In functions refer to 4.2.4 The In/Out Set-up Page, p39
General Purpose Outputs
Output Description
PWM 1 – 4
Turbo Wastegate
Bypass Air Control (BAC)
Dual Intake Valve
Torque Converter Control
Thermofan
Intercooler Fan
Shift Light
Aux Fuel Pump
Stall Saver
Staging Signal
Turbo Timer
NOS Switch
For further detail on the operation of the PWM outputs and digital outputs refer to CHAPTER
12 Digital Outputs & PWM Outputs, p85.