Item Brochure

STERLING
*
Nitrile Exam Gloves
QUALITY PERFORMANCE IN A
LATEXFREE GLOVE CLEARED
FOR USE WITH CHEMOTHERAPY
THE WORRY-FREE CHOICE…DESIGNED
FOR USE BY EVERYONE, EVERYWHERE
HALYARD
*
STERLING
*
Nitrile Exam Gloves provide
excellent fit and feel compared to latex. The new nitrile
formulation provides excellent comfort and stretch
compared to the previous glove, without sacrificing any
of STERLING
*
Nitrile’s barrier properties or durability.
They also have an Acceptable Quality Level (AQL) of 1.0.
That means STERLING
*
Exam Gloves are significantly less
likely to have critical defects than exam gloves that just
meet the ASTM 2.5 AQL requirement.
If you want to standardize on one exam glove for virtually
all your needs, facility-wide, STERLING
*
Nitrile is the
glove to choose.
PERFORMANCE IN A LATEXFREE
EXAM GLOVE
Latex allergy is a concern within the healthcare
industry. With STERLING
*
Nitrile Exam Gloves,
Halyard Health has created a latex-free glove with
the protection, comfort, and sensitivity of latex, at a
comparable value.
The Protection of Nitrile
- Halyard’s manufacturing process boosts the
tensile strength of nitrile—the force required
to break through the glove—to increase its
already superior barrier protection qualities.
The Tactile Sensitivity of Latex
- The process also allows a reduction in glove
thickness, which means that less force is
required to stretch the material. That provides
a latex-free glove with the dexterity and
tactile sensitivity of natural rubber latex.
SAVE SPACE AND WASTE
Standard length STERLING
*
Nitrile Exam Gloves come
in space saving 200 count dispenser boxes. That means
up to a 50% saving in the storage space you’d usually
devote to gloves. It also means fewer run-outs and
replacements in use, which can help increase convenience
and compliance. It also means there are fewer boxes to
discard, which means less waste for your facility.
SMARTPULL
*
DISPENSER BOX
The SMARTPULL
*
dispensing incorporates
2 separate openings on the box. The first,
smaller opening is used when the box is
full and helps control dispensing to lessen
waste from dropped gloves or multiple
dispensing. When the box is half empty,
the second, larger opening allows easier
access to the gloves.
Tested Chemotherapy Drug
and Concentration
Average Breakthrough
Detection Time (minutes)
Cyclophosphamide (20.0 mg/ml) No breakthrough up to 240 minutes
Doxorubicin HCI (2.00 mg/ml) No breakthrough up to 240 minutes
Etoposide (20.0 mg/ml) No breakthrough up to 240 minutes
5-Fluorouacil (50.0 mg/ml) No breakthrough up to 240 minutes
Paditaxel (Taxol) (6.0 mg/ml) No breakthrough up to 240 minutes
Cisplatin (1.0 mg/ml) No breakthrough up to 240 minutes
Dacarbazine (10.0 mg/ml) No breakthrough up to 240 minutes
Ifosfamide (50.0 mg/ml) No breakthrough up to 240 minutes
Mitoxantrone (2.0 mg/ml) No breakthrough up to 240 minutes
Vincristine sulfate (1.0 mg/ml) No breakthrough up to 240 minutes
Carmustine (3.3 mg/ml) Not for use with Carmustine
ThioTEPA (10.0 mg/ml) Not for use with ThioTEPA
200 Count Box
Saves Space and Waste!

Summary of content (2 pages)