Datasheet

27
Hamlin USA Tel: +1 920 648 3000 Fax: +1 920 648 3001 Email: sales.us@hamlin.com
Hamlin UK Tel: +44 (0)1379 649700 Fax: +44 (0)1379 649702 Email: sales.uk@hamlin.com
Hamlin Germany Tel: +49 (0) 6181 953660 Fax: +49 (0) 6181 9536666 Email: sales.de@hamlin.com
Hamectrol France Tel: +33 (0) 1 4687 0202 Fax: +33 (0) 1 4686 6786 Email: sales.fr@hamlin.com
TABLE 1 Form A Normally Normally Open Change Normally
Contact Type Open High Voltage Over Closed
Switch Type 12 34
Power Watt - max. 10 10 5 5
Voltage Switching Vdc - max. 200 300 175 175
Breakdown Vdc - min. 250 450 200 200
Current Switching A - max. 0.5 0.5 0.25 0.25
Carry A - max. 1.2 1.5 1.5 1.5
Resistance Contact, Initial - max. 0.2 0.2 0.2 0.2
Insulation - min. 10
10
10
10
10
9
10
9
Capacitance Contact pF - typ. 0.3 0.2 0.3 0.3
Temperature Operating °C -40 to +105 -20 to +105 -40 to +105 -40 to +105
Storage °C -65 to +105 -65 to +105 -65 to +105 -65 to +105
Time Operate ms - max. 1.0 1.0 3.0 3.0
Release ms - max. 1.0 1.0 3.0 3.0
Shock 11ms 1⁄2 sine G - max. 100 100 50 50
Vibration 50-2000 Hz G - max. 30 30 30 30
TABLE 3
Cable Type:-
24 AWG 7/32 PVC 105
o
C
UL1430/UL1569
Standard Lengths
SELECT CABLE
OPTION LENGTH
(in)
mm
01 (3,94) 100
02 (11,81) 300
03 (19,69) 500
04 (29,53) 750
05 (39,37) 1000
TABLE 4
Termination Options:-
SELECT DESCRIPTION
OPTION
(2 WIRE VERSIONS ILLUSTRATED)
A Tinned leads
B Crimped terminals
C 6.35mm fastons
D AMP MTE 2.54mm pitch
E JST XHP 2.5mm pitch
TABLE 2
Sensitivity Options:-
Activate Distances are approximate
using Hamlin 57065/57070 actuator
as illustrated
Switch AT before modification
Select Option S T U V
Switch
Pull In
Activate
Pull In
Activate
Pull In
Activate
Pull In
Activate
Type
AT
Distance
AT
Distance
AT
Distance
AT
Distance
Range
d
Range
d
Range
d
Range
d
(in) mm (in) mm (in) mm (in) mm
1 Normally Open 12-18 (.197)
17-23
(.276)
22-28
(.236)
27-33
(.177)
2 High Voltage 9,0 7,0 6,0 4,5
3 Change Over
15-20
(.295)
20-25
(.236)
25-30
(.197)
4 Normally Closed 7,5 6,0 5,0
CUSTOMER OPTIONS - Switching Specifications
CUSTOMER OPTIONS - Sensitivity, Cable Length and Termination Specification
ORDERING INFORMATION
DETAILS PROVIDED ON THIS DATA SHEET ARE PROVIDED FOR
INFORMATION PURPOSES ONLY AND SHOULD NOT BE RELIED
UPON AS BEING ACCURATE FOR ANY PARTICULAR PURPOSE.
Product performance may be affected by the application to which the
product is put. Upon request, HAMLIN will assist purchasers by
providing information specific to any particular application. HAMLIN
disclaims any and all liability whatsoever for any purchaser’s reliance
upon the information contained on this data sheet without further
consultation with authorised representatives of HAMLIN.
59036
Switch Type
Table 1
Table 3
Table 2
Table 4
Sensitivity
Cable Length
Termination
File E61760(N)
www.hamlin.com
X X XX X
DIMENSIONS (in) mm
59065/59070
Series 59065/59070
Features
2 part magnetically operated
proximity sensor
Threaded barrel with retaining nuts
Available as M8 (57070/59070) or
5/16 (57065/59065) size options
Customer defined sensitivity
Choice of cable length and
connector
Benefits
Simple installation and adjustment
using supplied retaining nuts
No standby power requirement
Operates through non-ferrous
materials such as wood, plastic or
aluminium
Simple installation and adjustment
Applications
Position and limit sensing
Security system switch
Linear actuators
Industrial process control
59065 & 59070 Threaded Barrel Features and Benefits
Actuator
Sensor
ISSUE No: 4 DATE: 1/5/3