TABLE 1 Form A Normally Normally Closed Change
Contact Type Closed High Voltage Over
Switch Type 453
Power Watt - max. 10 10 5
Voltage Switching Vdc - max. 200 300 175
Breakdown Vdc - min. 250 450 200
Current Switching A - max. 0.5 0.5 0.25
Carry A - max. 1.2 1.5 1.5
Resistance Contact,Initial - max. 0.2 0.2 0.2
Insulation - min. 10
10
10
10
10
9
Capacitance Contact pF - typ. 0.3 0.2 0.3
Temperature Operating °C -40 to +85 -20 to +85 -40 to +85
Storage °C -65 to +85 -65 to +85 -65 to +85
Time Operate ms - max. 1.0 1.0 3.0
Release ms - max. 1.0 1.0 3.0
Shock 11ms 1⁄2 sine G - max. 100 100 50
Vibration 50-2000 Hz G - max. 30 30 30
TABLE 2
Cable Type:-
BS 6500 3A 16/0.2 PVC
DOUBLE INSULATED
Standard Lengths
SELECT CABLE
OPTION LENGTH
(in)
mm
01 (3,94) 100
02 (11,81) 300
03 (19,69) 500
04 (29,53) 750
05 (39,37) 1000
TABLE 3
Termination Options:-
SELECT DESCRIPTION
OPTION
(2 WIRE VERSIONS ILLUSTRATED)
A or F Tinned or untinned leads
B Crimped terminals
C 6.35mm fastons
ACTIVATION
CUSTOMER OPTIONS - Switching Specifications
CUSTOMER OPTIONS - Cable Length and Termination Specification
ORDERING INFORMATION
DETAILS PROVIDED ON THIS DATA SHEET ARE PROVIDED FOR
INFORMATION PURPOSES ONLY AND SHOULD NOT BE RELIED
UPON AS BEING ACCURATE FOR ANY PARTICULAR PURPOSE.
Product performance may be affected by the application to which the
product is put. Upon request,HAMLIN will assist purchasers by
providing information specific to any particular application. HAMLIN
disclaims any and all liability whatsoever for any purchaser’s reliance
upon the information contained on this data sheet without further
consultation with authorised representatives of HAMLIN.
59036
Switch Type
Table 1
Table 2
Table 3
Sensitivity
Cable Length
Termination
www.hamlin.com
X T XX X
DIMENSIONS (in) mm
59090
Series 59090
Features
Sensor and magnet contained in
single housing
Sensor operates when ferrous vane
passes through slot
Normally closed standard,normally
closed high voltage or change over
options
Choice of cable length and connector
Benefits
Quick and reliable single screw
mounting with location feature
No standby power requirement
Hermetically sealed, magnetically
operated contacts continue to
operate long after optical and other
technologies fail due to
contamination
Applications
Position and limit sensing
Security system switch
Linear actuators
Industrial process control
Shaft rotation sensing